{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME08K2F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME08K2F7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME08K2F7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME08K2F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME, DOL reversing combination starter, GV2ME08K2F7, 2.5...4 A, 110 V AC control.","salesMarkdown":"The GV2ME08K2F7 is a DOL reversing combination starter from the TeSys GV2-ME range, integrating a GV2ME motor circuit breaker, a GV2AF01 combination block, and a 3-pole reversing contactor into a single assembly. Thermal protection adjusts from 2.5 to 4 A, and the control circuit runs on 110 V AC. This is a reversing starter — it handles forward/reverse motor control in one package, saving panel space over discrete components. The 2.5...4 A thermal adjustment range sets the motor protection band — you set the dial to match your full-load current. This covers small three-phase motors in the 1.1 to 2.2 kW range at 400/415 V and 500 V supplies. Breaking capacity is 50 kA at 400/415 V and 500 V, certified to IEC 60947-4-1. That's high for a compact starter — it can interrupt a bolted fault up to 50 kA without upstream fuses or a bigger breaker, provided the coordination type (Type 1) is acceptable for your installation. Type 1 means the starter may not be serviceable after a fault; the contactor or breaker may need replacement. The magnetic trip is set at 51 A, which clears short-circuit conditions fast. The 3-pole design (3P) matches standard three-phase motor circuits. Dimensions are 45 mm wide, 152 mm high, 87 mm deep — a 45 mm footprint per pole, so it fits standard 45 mm-wide DIN-rail slots.","metaTitle":"Schneider GV2ME08K2F7 TeSys reversing motor starter, 2.5-4 A","metaDescription":"Obsolete DOL reversing combination starter. 2.5-4 A thermal range, 50 kA breaking capacity at 400 V, AC-3. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 motor circuit breaker type GV2ME 1 combination block GV2AF01 1 3-pole reversing contactor","Motor starter type":"Reversing","Utilisation category":"AC-3","Magnetic tripping current":"51 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"110 V AC 50/60 Hz","Thermal Protection Adjustment Range":"2.5...4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1364c8455ebd7f65230bbe282e1f16df.pdf","sourceUrl":"https://www.se.com/uk/en/product/GV2ME08K2F7/dol-reversing-combination-starter-tesys-gv2me-2-5-4-a-110-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME08K2F7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this reversing starter?","answer":"Thermal protection adjustment range is 2.5...4 A. Breaking capacity is 50 kA at 400/415 V and 500 V AC, conforming to IEC 60947-4-1. Control voltage is 110 V AC 50/60 Hz. It is rated AC-3 for motor starting duty."},{"question":"How do I source this obsolete part?","answer":"Submit an RFQ. We can search surplus and broker inventory for available units. Since there is no confirmed direct replacement, the RFQ should note the thermal range, control voltage, and reversing configuration so we can identify alternatives if stock is exhausted."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME08K2F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME08K2F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}