{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME106","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME106","canonicalUrl":"https://aoctrl.com/schneider/GV2ME106","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME106","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys GV2 GV2ME106 motor circuit breaker, 3-pole, 6.3 A rated, thermal-magnetic, breaking capacity 100 kA at 400 V AC, IP20.","salesMarkdown":"## Device overview The Schneider GV2ME106 is a 3-pole motor circuit breaker from the TeSys GV2 range, sized for protecting 2.2 kW motors at 400 V or 3 kW at 500 V. Its thermal-magnetic trip unit handles sustained overloads and short circuits with a 6.3 A continuous rating. Magnetic trip is fixed at 91 A, so it clears fast on a solid bolted fault. ## Mounting and installation Horizontal or vertical orientation is acceptable. Terminal lugs accept ring terminals from 1 to 6 mm², and the 45 mm width leaves room for adjacent units in a motor starter combination. IP20 finger-safe enclosure with IK04 impact resistance. Fire rating meets 960 °C glow-wire test per IEC 60695-2-11. Designed and tested to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and relevant sections of IEC/EN 60335. Phase-failure sensitive per IEC 60947-4-1; suitable for isolation per IEC 60947-1.","metaTitle":"Schneider GV2ME106 Mtr Ckt Breaker 6.3A 3P 100kA","metaDescription":"GV2ME106 motor circuit breaker from Schneider TeSys GV2, 6.3 A rated, 3 poles, 100 kA breaking capacity at 400 V, thermal-magnetic, UL/CSA listed. Active production, source via RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"3.09 in (78.5 mm)","Range":"TeSys Deca","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US10I1122367","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)","Control Type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"2.2 kW 400/415 V AC 50/60 Hz 3 kW 500 V AC 50/60 Hz 4 kW 690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"0.5 in (13.5 mm) without spreader","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminal","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"6.3 A","Operating altitude":"<= 6561.68 ft (2000 m)","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1","Electrical durability":"100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks 30 Gn for 11 ms Vibrations 5 Gn, 5...150 Hz","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit lugs-ring terminals 2 0.002...0.009 in² (1...6 mm²)solid Power circuit lugs-ring terminals 2 0.002...0.009 in² (1.5...6 mm²)flexible without cable end Power circuit lugs-ring terminals 2 0.002...0.006 in² (1...4 mm²)flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"91 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Thermal protection adjustment range":"4...6.3 A IEC 60947-2","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"6.3 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 75 % 690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$170.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b19f908dcb3a3c888c72d74140ca8c6d.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME106/alternatives.json"},"ai":{"faq":[{"question":"What compliance standards does the GV2ME106 meet?","answer":"It is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and portions of IEC/EN 60335. It is also phase-failure sensitive and suitable for isolation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME106","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME106 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}