{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME10AN11TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME10AN11TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2ME10AN11TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME10AN11TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2ME10AN11TQ, 6.3 A rated current, 3-pole, thermal-magnetic trip, 100 kA breaking capacity at 400 V AC.","salesMarkdown":"Rated at 6.3 A continuous (In), it's sized for a 2.2 kW motor on a 400/415 V three-phase supply, or up to 4 kW at 690 V. Breaking capacity is 100 kA Icu at 400/415 V AC per IEC 60947-2, which means it can safely interrupt a fault current up to that level without welding contacts or cascading upstream — a strong SCCR figure for a 6 A frame. IP20 finger-safe protection when open-mounted, so it's suitable for enclosed panels where the front face is behind a door. The dark grey housing carries an IK04 impact rating — tough enough for routine panel access. Wiring is via screw-clamp terminals accepting up to 6 mm² solid or 4 mm² flexible with ferrule. Torque to 1.7 N·m. The power circuit can take two conductors per terminal, handy for daisy-chaining to a contactor or overload relay. ## Protection features and durability Phase-failure sensitive per IEC 60947-4-1 — it will trip if one phase drops out, preventing single-phasing damage to the motor. Rated for uninterrupted duty (unlimited on-time) per IEC 60947-4-1. Electrical durability is 100,000 cycles at rated current in AC-3 (motor switching) duty; mechanical durability matches at 100,000 cycles. That's a solid service life for a panel-mounted motor starter. Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor/motor-starter standard), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1 for North American installations. Also tested to IEC/EN 60335 for appliance applications (Annex JJ and Clause 30.2 glow-wire). Fire resistance tested to 960 °C per IEC 60695-2-11 (glow-wire). Climatic withstand conforms to IACS for marine environments. Operating altitude is limited to 2000 m without derating.","metaTitle":"Schneider Electric GV2ME10AN11TQ Motor Circuit Breaker, 6.3","metaDescription":"Schneider Electric GV2ME10AN11TQ TeSys GV2 motor circuit breaker, 6.3 A rated current, thermal-magnetic trip, 100 kA breaking capacity at 400 V, 3-pole, IP20.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"54 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"2.2 kW at 400/415 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz 4 kW at 690 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 20","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"6.3 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529 (open mounted)","Magnetic tripping current":"91 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC side","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"600 V AC 50/60 Hz conforming to UL 508 690 V AC 50/60 Hz conforming to IEC 60947-2 600 V AC 50/60 Hz conforming to CSA C22.2 No 14","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"4...6.3 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...40 °C in enclosure -20...60 °C open mounted","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"6.3 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/GV2ME10AN11TQ/motor-circuit-breaker-tesys-deca-4-6-3-a-3-3d-thermal-magnetic-trip-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME10AN11TQ/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the GV2ME10AN11TQ?","answer":"Rated current is 6.3 A (In). Breaking capacity is 100 kA Icu at 400/415 V AC, 50 kA at 500 V, and 3 kA at 690 V. Motor power ratings are 2.2 kW at 400/415 V, 3 kW at 500 V, and 4 kW at 690 V. Magnetic trip is fixed at 91 A."},{"question":"What standards does the GV2ME10AN11TQ comply with?","answer":"It complies with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40 Annex JJ and IEC/EN 60335-1 Clause 30.2 for glow-wire testing."},{"question":"What is the physical size of the GV2ME10AN11TQ?","answer":"Dimensions are 89 mm high, 54 mm wide, and 78.5 mm deep. It mounts on a 35 mm DIN rail or to a panel with an adaptor plate."},{"question":"Does the GV2ME10AN11TQ have phase failure protection?","answer":"Yes, it is phase-failure sensitive per IEC 60947-4-1, so it will trip if one phase is lost to prevent single-phasing motor damage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME10AN11TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME10AN11TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}