{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME10K1BW3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME10K1BW3","canonicalUrl":"https://aoctrl.com/schneider/GV2ME10K1BW3","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME10K1BW3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca Frame 2, GV2ME10K1BW3, DOL combination starter, 4-6.3 A thermal range, 24 V DC coil.","salesMarkdown":"The GV2ME10K1BW3 is a direct-on-line (DOL) combination motor starter from the Schneider Electric TeSys range, built around a GV2ME10 motor circuit breaker and an LC1K06 contactor joined by a GV2AF01 combination block. It's a pre-assembled, non-reversing 3-pole starter rated for AC-3 and AC-3e utilisation categories — meaning it's designed for starting and stopping squirrel-cage motors under load, not just resistive switching. The thermal protection adjustment range spans 4 to 6.3 A, which covers small motor loads in the 2.2 kW to 3 kW band depending on line voltage. At 400/415 V AC it delivers 2.2 kW motor power; at 440 V it's rated for both 2.2 kW and 3 kW; at 500 V it handles 3 kW. The magnetic trip is fixed at 78 A, so instantaneous short-circuit protection kicks in well above the thermal setting — that's standard for motor starting inrush. Breaking capacity is 50 kA Iq at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1. That 50 kA figure is the prospective fault current the starter can safely interrupt — important when the panel's available fault current is high. Coordination is Type 1, meaning after a short circuit the starter may need contactor or breaker replacement, but the installation is protected from fire or arc-flash. Control voltage is 24 V DC, which is common in PLC-driven panels and safety circuits. The coil on the LC1K06 contactor pulls in at 24 VDC nominal; verify your control transformer or power supply can deliver the inrush current for the contactor holding coil. The 24 VDC coil also simplifies integration with solid-state outputs from a safety relay or PLC. Physical footprint: 45 mm wide, 152 mm high, 87 mm deep. That 45 mm width is a single 9 mm DIN-module increment — it occupies two standard 22.5 mm module positions on the DIN rail. The depth of 87 mm means it clears most standard 100 mm-deep enclosures, but check gland-plate clearance if mounting near the back wall.","metaTitle":"Schneider TeSys GV2ME10K1BW3 Motor Starter, 4-6.3 A, 24 VDC","metaDescription":"Schneider Electric TeSys GV2ME10K1BW3 DOL motor starter. Active lifecycle. 4-6.3 A thermal adjustment, 24 VDC coil, 50 kA breaking capacity at 400 V. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","title":"GV2ME10K1BW3","Height":"152 mm","description":"DOL combination starter,TeSys Deca Frame 2,GV2ME10 and LC1K06,4-6.3A,110V AC","Motor power kW":"2.2 kW at 400/415 V AC 50/60 Hz 2.2 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 3-pole contactor 1 motor circuit breaker type GV2ME 1 combination block GV2AF01","Motor starter type":"Non reversing","Utilisation category":"AC-3 AC-3e","Magnetic tripping current":"78 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"24 V DC","Thermal Protection Adjustment Range":"4...6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$154.39","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c7a89c1bd5522584c33359740cd0d95f.pdf","sourceUrl":"https://www.se.com/hk/en/product/GV2ME10K1BW3/dol-combination-startertesys-deca-frame-2gv2me10-and-lc1k0646-3a110v-ac/"},"ai":{"faq":[{"question":"What are the key ratings for this motor starter?","answer":"Thermal protection adjustment range is 4-6.3 A. Motor power is 2.2 kW at 400/415 V, up to 3 kW at 500 V. Breaking capacity is 50 kA at 400-500 V. Control voltage is 24 V DC. Magnetic trip is fixed at 78 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME10K1BW3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME10K1BW3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}