{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME10K1F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME10K1F7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME10K1F7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME10K1F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME series, DOL combination starter GV2ME10K1F7, thermal protection 4…6.3 A, control circuit 110 V AC 50/60 Hz, 3-pole non-reversing.","salesMarkdown":"The GV2ME10K1F7 is a direct-on-line (DOL) combination motor starter from the Schneider TeSys GV2-ME range. It integrates a 3-pole motor circuit breaker and a 3-pole contactor into one block, with a GV2AF01 auxiliary contact block included. The thermal protection adjustment range is 4…6.3 A, and the magnetic tripping current is fixed at 78 A — so it catches short-circuit faults fast while the thermal bimetal handles overloads according to the AC-3 utilisation category for squirrel-cage motors. The control circuit voltage is 110 V AC 50/60 Hz. Breaking capacity is 50 kA Iq at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1 — meaning it can safely interrupt fault currents up to 50 kA at those voltages without welding the contacts or rupturing the enclosure. Coordination type is Type 1, so after a fault the starter may need contact replacement, but the installation stays intact. For a BOM freeze or line-down replacement, the key ratings to match are the thermal range (4…6.3 A), the 110 V AC coil, the 3-pole configuration, and the 50 kA breaking capacity at your supply voltage. The 4…6.3 A thermal adjustment range covers motors with a full-load current in that band — typically a 2.2 kW motor at 400/415 V or 440 V, or a 3 kW motor at 500 V, as the motor power kW entries confirm. The 78 A magnetic trip is fixed and non-adjustable; it provides short-circuit protection without nuisance tripping on motor inrush, which for a 6.3 A full-load motor is roughly 12× the top of the thermal range — well above the typical 6-8× inrush multiplier. The 50 kA breaking capacity at 400/415 V, 440 V, and 500 V AC means this starter can be installed on systems with high available fault current — common in industrial distribution close to a transformer. The Type 1 coordination means the starter may be damaged after a fault, but the upstream protection (typically a circuit breaker or fuse) clears the fault without requiring a full panel rebuild.","metaTitle":"Schneider TeSys GV2ME10K1F7 Motor Starter, 4-6.3 A, 110 V AC","metaDescription":"Obsolete DOL combination starter from Schneider TeSys GV2-ME series. Thermal range 4-6.3 A, 110 V AC coil, 50 kA breaking capacity. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"2.2 kW at 400/415 V AC 50/60 Hz 2.2 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 combination block GV2AF01 1 3-pole contactor 1 motor circuit breaker type GV2ME","Motor starter type":"Non reversing","Utilisation category":"AC-3","Magnetic tripping current":"78 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"110 V AC 50/60 Hz","Thermal Protection Adjustment Range":"4...6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fcb897e3264cf2dccfb2a6cc9661d8a7.pdf","sourceUrl":"https://www.se.com/nl/en/product/GV2ME10K1F7/dol-combination-starter-tesys-gv2me-4-6-3-a-110-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME10K1F7/alternatives.json"},"ai":{"faq":[{"question":"What replaces the GV2ME10K1F7?","answer":"No official successor order code is listed in the lifecycle record. A current-series replacement from the TeSys GV3P or TeSys Deca range with matching thermal range (4…6.3 A), 110 V AC coil, 3-pole, and 50 kA breaking capacity would be the closest functional equivalent, but dimensions and auxiliary contact arrangements must be verified against the panel layout."},{"question":"What are the key ratings for the GV2ME10K1F7?","answer":"Thermal protection adjustment range 4…6.3 A, magnetic tripping current 78 A, control circuit voltage 110 V AC 50/60 Hz, breaking capacity 50 kA at 400/415 V, 440 V, and 500 V AC, motor power 2.2 kW at 400/415 V and 3 kW at 500 V, all per IEC 60947-4-1."},{"question":"How do I source this obsolete part?","answer":"Submit an RFQ with your target quantity. We locate available units from surplus inventory or broker channels. No stock or lead time is quoted here — the supply posture is quoted to order against a firm request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME10K1F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME10K1F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}