{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME10K1P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME10K1P7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME10K1P7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME10K1P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME DOL combination starter, GV2ME10K1P7, 4...6.3 A thermal adjustment, 230 V AC control, 50 kA breaking capacity.","salesMarkdown":"The GV2ME10K1P7 is a TeSys GV2-ME direct-on-line (DOL) combination starter from Schneider Electric. It integrates a 3-pole contactor, a GV2ME motor circuit breaker, and a GV2AF01 combination block into a single unit for non-reversing motor starting. The thermal protection adjustment range spans 4 to 6.3 A, and the magnetic tripping current is set at 78 A. This means the overload relay is sized for motors drawing between 4 and 6.3 A full-load current, while the magnetic short-circuit trip clears faults above 78 A instantaneously. The unit handles motor power up to 2.2 kW at 400/415 V AC and 3 kW at 500 V AC, making it suitable for small three-phase induction motors in pump, fan, or conveyor applications. Breaking capacity is rated at 50 kA Iq at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1. Coordination type is Type 1, meaning the starter may need contactor replacement after a fault but the breaker resets. If the application can accept a parametric substitute, the TeSys GV2ME series includes active variants with the same 4...6.3 A thermal range and 230 V AC coil, though the exact order code and physical footprint should be verified against the panel layout. ## Physical integration Dimensions are 152 mm height, 45 mm width, and 87 mm depth.","metaTitle":"TeSys GV2ME10K1P7 DOL Starter, 4...6.3 A, 50 kA Breaking","metaDescription":"Obsolete TeSys GV2ME10K1P7 DOL combination starter. 4...6.3 A thermal range, 230 V AC coil, 50 kA breaking capacity at 400 V. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"2.2 kW at 400/415 V AC 50/60 Hz 2.2 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 3-pole contactor 1 motor circuit breaker type GV2ME 1 combination block GV2AF01","Motor starter type":"Non reversing","Utilisation category":"AC-3","Magnetic tripping current":"78 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"230 V AC 50/60 Hz","Thermal Protection Adjustment Range":"4...6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d58e54cd29a6d64e06865ac3176520fc.pdf","sourceUrl":"https://www.se.com/nl/en/product/GV2ME10K1P7/dol-combination-starter-tesys-gv2me-4-6-3-a-230-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME10K1P7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to GV2ME10K1P7?","answer":"The TeSys GV2ME series includes active variants with the same 4...6.3 A thermal adjustment range and 230 V AC control voltage. Verify the exact order code and physical dimensions against your panel layout before substituting."},{"question":"What is the breaking capacity of this starter?","answer":"The breaking capacity is 50 kA Iq at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1. This allows it to safely interrupt high fault currents."},{"question":"What motor power range does this cover?","answer":"It handles motor power up to 2.2 kW at 400/415 V AC and 3 kW at 500 V AC, with a thermal adjustment range of 4 to 6.3 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME10K1P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME10K1P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}