{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME10K2U7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME10K2U7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME10K2U7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME10K2U7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME reversing DOL combination starter, GV2ME10K2U7, thermal protection 4...6.3 A, 230...240 V AC coil, 3-pole.","salesMarkdown":"It is rated for AC-3 duty (motor switching) and covers a thermal protection adjustment range of 4...6.3 A, so it is sized for small three-phase induction motors in that current window. The coordination type is Type 1, so after a fault the starter may need contact replacement, but the breaker and contactor are sized to clear the fault without upstream damage. Motor power ratings span 2.2 kW at 400/415 V up to 3 kW at 500 V, which maps to the 4...6.3 A thermal range in practice. The magnetic tripping current is fixed at 78 A — this is the instantaneous magnetic trip that clears a short-circuit or stall condition. It is not adjustable; the thermal adjustment range (4...6.3 A) is what you set for the motor's full-load current. The 45 mm width (3-module DIN footprint) and 152 mm height mean it occupies one standard DIN-rail position in the enclosure, with 87 mm depth behind the panel. This is a reversing DOL starter — it handles forward/reverse control of a three-phase motor directly across the line, without a VFD. Typical loads are small conveyors, hoists, gate operators, or any application where the motor must run in both directions and the starting current inrush (typically 6-8x FLA for a standard induction motor) is acceptable. The reversing contactor pair is interlocked mechanically and electrically inside the assembly, so you do not need external interlocking relays.","metaTitle":"Schneider Electric GV2ME10K2U7 TeSys reversing motor starter","metaDescription":"Schneider Electric GV2ME10K2U7 TeSys reversing DOL motor starter. Thermal range 4-6.3 A, 230/240 V AC coil, 50 kA breaking capacity. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","title":"GV2ME10K2U7","Height":"152 mm","description":"DOL reversing combination starter - TeSys GV2-ME - 4...6.3 A - 230...240 V AC","Motor power kW":"2.2 kW at 400/415 V AC 50/60 Hz 2.2 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 combination block GV2AF01 1 motor circuit breaker type GV2ME 1 3-pole reversing contactor","Motor starter type":"Reversing","Utilisation category":"AC-3","Magnetic tripping current":"78 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"230/240 V AC 50/60 Hz","Thermal Protection Adjustment Range":"4...6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8c98cc182bac6bd2e8303cfc5eded354.pdf","sourceUrl":"https://www.se.com/nl/en/product/GV2ME10K2U7/dol-reversing-combination-starter-tesys-gv2me-4-6-3-a-230-240-v-ac/"},"ai":{"faq":[{"question":"What is the thermal protection adjustment range?","answer":"The thermal overload relay inside the motor circuit breaker adjusts from 4 A to 6.3 A. Set it to the motor's nameplate full-load current within that window."},{"question":"What control voltage does this starter require?","answer":"The coil is rated for 230/240 V AC at 50/60 Hz. The reversing contactor and the motor circuit breaker share this control voltage."},{"question":"What breaking capacity does it offer?","answer":"50 kA at 400/415 V AC and at 440 V AC and at 500 V AC, all conforming to IEC 60947-4-1. This is the rated short-circuit breaking capacity (Iq)."},{"question":"What is the physical size of the GV2ME10K2U7?","answer":"Width 45 mm, height 152 mm, depth 87 mm. It mounts on a standard DIN rail and occupies one 3-module position."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME10K2U7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME10K2U7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}