{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME143","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME143","canonicalUrl":"https://aoctrl.com/schneider/GV2ME143","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME143","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME143 motor circuit breaker, 3-pole, 10 A, thermal-magnetic, 100 kA breaking capacity.","salesMarkdown":"It uses a thermal-magnetic trip unit for overload and short-circuit protection, with a magnetic trip threshold of 149 A. That rating holds up to 690 V AC with lower values — 15 kA at 440 V, 10 kA at 500 V, 3 kA at 690 V. Dimensions are 101 mm height, 45 mm width, 78.5 mm depth — slots into a standard enclosure without surprises. Spring terminals accept 1 to 6 mm² solid or 1.5 to 4 mm² flexible wire. Two conductors per terminal allowed, which saves space when looping through. Compliant with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Also tested for glow-wire at 960 °C per IEC 60695-2-11. IP20 protected, IK04 impact resistance.","metaTitle":"GV2ME143 TeSys Deca Motor Circuit Breaker 10 A","metaDescription":"Current-production GV2ME143 motor circuit breaker, 10 A, 3P, 100 kA breaking capacity at 400 V AC. UL, CSA, IEC listed. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"101 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz","Product weight":"0.28 kg","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"10 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: spring terminals 2 cable(s) 1...6 mm² - solid Power circuit: spring terminals 2 cable(s) 1.5...4 mm² - flexible without cable end Power circuit: spring terminals 2 cable(s) 1...4 mm² - flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"149 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"6...10 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"10 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.37","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b19f908dcb3a3c888c72d74140ca8c6d.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME143/alternatives.json"},"ai":{"faq":[{"question":"What is the GV2ME143's depth?","answer":"The GV2ME143 has a depth of 78.5 mm."},{"question":"What range and series does the GV2ME143 belong to?","answer":"It is part of the TeSys Deca range, TeSys GV2 series."},{"question":"What compliance documentation is available for the GV2ME143?","answer":"The GV2ME143 is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. It also meets glow-wire and IP20 requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME143","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME143 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}