{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME14K1FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME14K1FE7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME14K1FE7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME14K1FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME DOL combination starter, GV2ME14K1FE7, 6-10 A thermal adjustment, 115 V AC 50/60 Hz control voltage.","salesMarkdown":"The GV2ME14K1FE7 is a non-reversing DOL combination starter from the TeSys GV2-ME range, integrating a 3-pole motor circuit breaker and a 3-pole contactor into a single block with the GV2AF01 combination block. The thermal protection adjustment range of 6-10 A sets the overload trip point for the motor, while the magnetic tripping current of 138 A handles short-circuit protection. Rated for AC-3 utilisation category, this starter is designed for direct-on-line starting of three-phase squirrel-cage induction motors. Motor power ratings span 3 kW at 400/415 V up to 5.5 kW at 500 V AC, making it suitable for pumps, fans, compressors, and conveyors in industrial control panels. The 45 mm width and 152 mm height fit standard DIN-rail enclosures with typical panel fill factors. The 6-10 A thermal adjustment range is the overload setting you dial in to match the motor's full-load current. Set it at the motor nameplate FLA — the magnetic trip at 138 A is fixed and handles short-circuits only, not overloads. Coordination is Type 1, meaning the starter may need contactor replacement after a fault, but the breaker resets. The 115 V AC control voltage is the coil rating. The depth of 87 mm matters when fitting into shallow enclosures or when gland plates limit rear clearance.","metaTitle":"Schneider GV2ME14K1FE7 TeSys DOL Starter, 6-10 A, 115 V AC","metaDescription":"Obsolete TeSys GV2-ME DOL combination starter. 6-10 A thermal range, 115 V AC coil, 50 kA breaking capacity at 400 V. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 combination block GV2AF01 1 motor circuit breaker type GV2ME 1 3-pole contactor","Motor starter type":"Non reversing","Utilisation category":"AC-3","Magnetic tripping current":"138 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"115 V AC 50/60 Hz","Thermal Protection Adjustment Range":"6...10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/52e70b3a8946e390424a33fa5ea83b69.pdf","sourceUrl":"https://www.se.com/ie/en/product/GV2ME14K1FE7/dol-combination-starter-tesys-gv2me-6-10-a-115-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME14K1FE7/alternatives.json"},"ai":{"faq":[{"question":"What replaces the GV2ME14K1FE7?","answer":"No official successor order code is listed in the lifecycle record. For a direct replacement, you would need to evaluate current TeSys GV3P or GV4P motor starters with similar ratings (6-10 A thermal, 115 V AC coil) and adjust the panel layout accordingly."},{"question":"How do I source this obsolete part?","answer":"We source the GV2ME14K1FE7 to order against an RFQ from surplus and broker inventory. Submit your quantity for a quote — this covers you while remaining stock lasts."},{"question":"What are the key ratings for fit verification?","answer":"Thermal protection adjustment range 6-10 A, magnetic tripping current 138 A, control circuit voltage 115 V AC 50/60 Hz, breaking capacity 50 kA at 400/415 V AC (IEC 60947-4-1), and motor power up to 5.5 kW at 500 V AC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME14K1FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME14K1FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}