{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME14K1M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME14K1M7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME14K1M7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME14K1M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME series, GV2ME14K1M7, DOL combination starter, 6...10 A, 220...230 V AC.","salesMarkdown":"The GV2ME14K1M7 is a non-reversing DOL combination starter from the TeSys GV2-ME range, integrating a GV2ME motor circuit breaker, a 3-pole contactor, and a GV2AF01 combination block into one unit. It provides thermal and magnetic protection for three-phase motors, with a thermal adjustment range of 6 to 10 A and a magnetic tripping threshold of 138 A. Rated for AC-3 utilisation category, it handles motor switching duty at up to 5.5 kW on 500 V AC supply, with breaking capacity reaching 50 kA at 400/415 V AC per IEC 60947-4-1. Breaking capacity of 50 kA at 400/415 V AC means this starter can safely interrupt a fault current up to that level without upstream damage, provided the coordination type (Type 1) is acceptable for your panel — Type 1 allows the starter to be damaged after a fault, requiring replacement. It is a self-contained unit: wire the incoming three-phase supply to the breaker input, the motor leads to the contactor output, and the control voltage (220/230 V AC) to the coil terminals.","metaTitle":"Schneider Electric GV2ME14K1M7 TeSys DOL Starter, 6-10 A, 22","metaDescription":"GV2ME14K1M7 DOL combination starter by Schneider Electric. TeSys GV2-ME series, 6-10 A thermal adjustment, 220-230 V AC coil. Obsolete; sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 motor circuit breaker type GV2ME 1 3-pole contactor 1 combination block GV2AF01","Motor starter type":"Non reversing","Utilisation category":"AC-3","Magnetic tripping current":"138 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"220/230 V AC 50/60 Hz","Thermal Protection Adjustment Range":"6...10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f403cb9f3886a72648659891cbfcb0c8.pdf","sourceUrl":"https://www.se.com/nl/en/product/GV2ME14K1M7/dol-combination-starter-tesys-gv2me-6-10-a-220-230-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME14K1M7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this motor starter?","answer":"Thermal adjustment range 6-10 A, magnetic trip at 138 A, control voltage 220/230 V AC 50/60 Hz, breaking capacity 50 kA at 400/415 V AC (IEC 60947-4-1), and motor power up to 5.5 kW at 500 V AC."},{"question":"How do I source this obsolete part?","answer":"Since it is obsolete, sourcing is through surplus or independent distributor channels. Submit an RFQ for current availability and pricing; it is not stocked as a standard production item."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME14K1M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME14K1M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}