{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME14K2B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME14K2B7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME14K2B7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME14K2B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME DOL reversing combination starter, GV2ME14K2B7, 6...10 A thermal protection, 24 V AC 50/60 Hz coil, 3-pole.","salesMarkdown":"The GV2ME14K2B7 is a DOL reversing combination starter from the TeSys GV2-ME range, integrating a motor circuit breaker, a 3-pole reversing contactor, and a GV2AF01 combination block into one assembly. It provides thermal protection adjustable from 6 to 10 A and magnetic short-circuit protection tripping at 138 A, all in a 45 mm wide, 152 mm high, 87 mm deep package that clips onto a DIN rail. Rated for AC-3 utilisation category, it handles motor loads up to 3 kW at 400/415 V AC, 4 kW at 440 V, and 5.5 kW at 500 V. Breaking capacity is 50 kA at 400/415 V AC, 15 kA at 440 V, and 6 kA at 500 V, all conforming to IEC 60947-4-1. This is Type 1 coordination, meaning the starter may need contact replacement after a fault — acceptable for most industrial lines where uptime is restored by swapping the unit rather than clearing welded contacts. Schneider Electric lists the GV2ME14K2B7 as obsolete. No official successor order code exists, so a direct form-fit-function replacement within the current TeSys range must be identified by comparing the thermal adjustment range (6-10 A), 24 V AC coil, reversing configuration, and DIN-rail footprint.","metaTitle":"Schneider GV2ME14K2B7 TeSys Reversing Starter, 6-10 A, 24 V","metaDescription":"Obsolete DOL reversing combination starter, TeSys GV2-ME, 6-10 A thermal range, 24 V AC coil. Sourced to order against RFQ. Breaking capacity 50 kA at 400 V.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 combination block GV2AF01 1 motor circuit breaker type GV2ME 1 3-pole reversing contactor","Motor starter type":"Reversing","Utilisation category":"AC-3","Magnetic tripping current":"138 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"24 V AC 50/60 Hz","Thermal Protection Adjustment Range":"6...10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48b670bf5ed2fd5490c645dc04553f14.pdf","sourceUrl":"https://www.se.com/sg/en/product/GV2ME14K2B7/dol-reversing-combination-starter-tesys-gv2me-6-10-a-24-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME14K2B7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the GV2ME14K2B7?","answer":"Thermal protection adjustment range is 6 to 10 A. Magnetic trip is at 138 A. Motor power ratings: 3 kW at 400/415 V, 4 kW at 440 V, 5.5 kW at 500 V. Breaking capacity is 50 kA at 400/415 V. Control voltage is 24 V AC 50/60 Hz."},{"question":"How do I source the GV2ME14K2B7 now that it is obsolete?","answer":"This part is sourced through independent surplus and broker channels. Submit an RFQ for current availability and pricing — there is no standard lead time or stock position."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME14K2B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME14K2B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}