{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME14K2U7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME14K2U7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME14K2U7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME14K2U7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME reversing DOL combination motor starter, GV2ME14K2U7, thermal adjustment 6...10 A, control voltage 230/240 V AC, breaking capacity 50 kA at 400 V.","salesMarkdown":"The GV2ME14K2U7 is a reversing DOL combination motor starter from the TeSys GV2-ME range, integrating a 3-pole motor circuit breaker, a 3-pole reversing contactor, and a combination block into a single unit. It is sized for reversing motor loads up to 3 kW at 400/415 V AC or 5.5 kW at 500 V AC in AC-3 duty, with a thermal protection adjustment range of 6...10 A. The 230/240 V AC control circuit voltage matches standard European panel supplies, and the reversing contactor pair handles direction switching without external interlocking — the mechanical interlock is built into the combination block. ## Breaking capacity and coordination — what the ratings mean The breaking capacity is 50 kA Iq at 400/415 V AC, certified to IEC 60947-4-1. At 500 V AC the breaking capacity drops to 6 kA, so verify the fault level at the point of installation if running on a 500 V line. The magnetic tripping current is fixed at 138 A, which is roughly 13.8 times the upper thermal setting of 10 A. That gives a fast magnetic trip for short-circuit conditions while the thermal bimetal handles overloads in the 6...10 A adjustment range. The combination block GV2AF01 is included, so the reversing contactor and breaker are mechanically interlocked and pre-wired — no additional bus bars or jumpers needed for the reversing function.","metaTitle":"Schneider Electric GV2ME14K2U7 TeSys reversing motor starter","metaDescription":"Schneider Electric GV2ME14K2U7 TeSys reversing DOL combination motor starter, 6-10 A thermal range, 230/240 V AC coil, 50 kA breaking capacity at 400 V. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","title":"GV2ME14K2U7","Height":"152 mm","description":"DOL reversing combination starter - TeSys GV2-ME - 6...10 A - 230...240 V AC","Motor power kW":"3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 motor circuit breaker type GV2ME 1 3-pole reversing contactor 1 combination block GV2AF01","Motor starter type":"Reversing","Utilisation category":"AC-3","Magnetic tripping current":"138 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"230/240 V AC 50/60 Hz","Thermal Protection Adjustment Range":"6...10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3608dfd81602339a392541aa38dcb5f2.pdf","sourceUrl":"https://www.se.com/ie/en/product/GV2ME14K2U7/dol-reversing-combination-starter-tesys-gv2me-6-10-a-230-240-v-ac/"},"ai":{"faq":[{"question":"What is the thermal protection adjustment range?","answer":"The thermal protection adjustment range is 6...10 A, set via the dial on the front of the motor circuit breaker section."},{"question":"What breaking capacity does it offer at 400 V?","answer":"It offers 50 kA Iq at 400/415 V AC, certified to IEC 60947-4-1 under Type 1 coordination."},{"question":"What is the control circuit voltage?","answer":"The control circuit voltage is 230/240 V AC, 50/60 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME14K2U7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME14K2U7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}