{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P01TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P01TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2P01TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P01TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2P01TQ, 0.16 A rated current, 3P, thermal-magnetic, 100 kA Icu at 400 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric GV2P01TQ is a TeSys GV2 motor circuit breaker, a 3-pole thermal-magnetic device rated at 0.16 A for motor protection. It's the smallest current rating in the GV2 family, sized for fractional-horsepower motors or control transformers where the full-load amps are under 0.2 A. The thermal element tracks motor heating; the magnetic trip at 1.93 A clears short circuits before the motor winding takes damage. The 45 mm width (three 15 mm modules) fits standard enclosure cutouts. Mounting position is horizontal or vertical, no derating required for orientation. Power terminals accept up to 6 mm² solid or 4 mm² flexible with ferrule, two conductors per clamp. Tightening torque is 1.7 N·m — a standard screwdriver setting, no special tool needed. IP20 finger-safe protection on the front; the IK04 impact rating means it survives a 0.5 J knock from a dropped tool during panel work. For a motor, that's the full-load current (FLA) it protects — so this breaker fits a motor drawing 0.16 A or less. The thermal-magnetic trip curve is fixed; there's no adjustment dial. The magnetic trip at 1.93 A (about 12x In) clears hard faults fast, while the thermal element handles overloads on a time curve that matches motor heating. Phase failure sensitivity is built in — if one phase drops, the breaker trips, protecting the motor from single-phasing. Electrical durability is 100,000 cycles at AC-3 (motor switching) at 415 V, which is high for a breaker this size; mechanical durability matches at 100,000 cycles. Power dissipation per pole is 2.5 W, so three poles dissipate 7.5 W total — negligible for panel thermal calculations but worth noting in a sealed enclosure.","metaTitle":"Schneider Electric GV2P01TQ TeSys GV2 Motor Circuit Breaker,","metaDescription":"Schneider Electric GV2P01TQ TeSys GV2 motor circuit breaker, 0.16 A thermal-magnetic, 100 kA Icu at 400 V, 3P, DIN rail. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"97 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws)","Control type":"Rotary handle","Network type":"AC","Product name":"TeSys GV2","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2P","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.16 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"1.93 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.1...0.16 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.16 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/534567302fba04db53d9be3282321fd7.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2P01TQ/motor-circuit-breaker-tesys-deca-3p-0-10-16-a-thermal-magneticc-screw-clamp-terminals-tq-24-units/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P01TQ/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does GV2P01TQ carry?","answer":"It carries UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC/EN 60947-2, IEC/EN 60947-4-1, and IEC/EN 60335-2-40 Annex JJ certifications. Fire resistance is tested to 960 °C per IEC 60695-2-11."},{"question":"What is the breaking capacity of GV2P01TQ?","answer":"Breaking capacity is 100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC 50/60 Hz per IEC 60947-2. This is consistent across the full voltage range."},{"question":"What is the closest alternative to GV2P01TQ in the TeSys GV2 family?","answer":"The GV2P01TQ is the 0.16 A variant. The next step up in the same form factor is the GV2P02TQ at 0.25 A, and the GV2P03TQ at 0.4 A. All share the same 45 mm width, DIN rail mount, and 100 kA breaking capacity — the only difference is the thermal-magnetic trip calibration."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P01TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P01TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}