{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P02TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P02TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2P02TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P02TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2P02TQ, motor circuit breaker, 3 poles, 0.25 A rated current, thermal-magnetic, 100 kA breaking capacity.","salesMarkdown":"## Motor Circuit Breaker for 0.25 A Protection The Schneider Electric GV2P02TQ is a TeSys Deca motor circuit breaker rated at 0.25 A, designed for protecting small motor loads up to 0.06 kW at 400/415 V AC. This high interrupting rating ensures coordination with upstream protection devices in a fault scenario, reducing the risk of cascading failures in the panel. ## Standards and Compliance for Tender Submissions Phase failure sensitivity is built in per IEC 60947-4-1, protecting the motor against single-phasing conditions. The 45 mm width and 89 mm height fit standard DIN-rail spacing; depth is 97 mm including the rotary handle. Accepts power circuit wiring: screw clamp terminals for 2 cables of 1 to 6 mm² solid or 1.5 to 6 mm² flexible without cable end, or 1 to 4 mm² flexible with cable end. Tightening torque is 1.7 N·m.","metaTitle":"Schneider Electric GV2P02TQ TeSys Deca Motor Circuit Breaker","metaDescription":"Schneider Electric GV2P02TQ TeSys Deca motor circuit breaker, 0.25 A rated current, thermal-magnetic trip, 100 kA breaking capacity. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"97 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws)","Control type":"Rotary handle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.06 kW at 400/415 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2P","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.25 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"3.08 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.16...0.25 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.25 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d67fdfa2a5b51032c48ba002ded28b99.pdf","sourceUrl":"https://www.se.com/eg/en/product/GV2P02TQ/motor-circuit-breaker-tesys-deca-3p-0-16-to-0-25a-thermal-magneticc-screw-clamp-terminals-tq-24-units/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P02TQ/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the GV2P02TQ?","answer":"Rated current In is 0.25 A, magnetic tripping current is 3.08 A, breaking capacity is 100 kA Icu at 400/415 V AC, and it is rated for motor protection up to 0.06 kW at 400/415 V AC."},{"question":"What compliance standards does the GV2P02TQ meet?","answer":"It complies with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC/EN 60335-2-40 Annex JJ, and IEC/EN 60335-1 Clause 30.2."},{"question":"How is the GV2P02TQ mounted and wired?","answer":"It mounts on a 35 mm DIN rail or directly to a panel with M4 screws. Power terminals accept 1 to 6 mm² solid or 1.5 to 6 mm² flexible wire, with a tightening torque of 1.7 N·m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P02TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P02TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}