{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P03AE11","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P03AE11","canonicalUrl":"https://aoctrl.com/schneider/GV2P03AE11","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P03AE11","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2P03AE11, 0.4 A, 3-pole, thermal-magnetic, 100 kA breaking capacity, IP20.","salesMarkdown":"The Schneider Electric GV2P03AE11 is a 3-pole motor circuit breaker from the TeSys GV2 series, rated at 0.4 A and designed for motor protection in industrial control panels. It combines a thermal-magnetic trip unit with a rotary handle for manual control and isolation. The 0.4 A rating protects a 0.09 kW motor at 400/415 V AC, making it suited for small fractional-horsepower loads like fans, pumps, or conveyors in light-duty applications. Breaking capacity is 100 kA Icu at 400/415 V AC, which means it can safely interrupt a fault current up to 100,000 A without failing. The thermal-magnetic trip provides overload protection via a bimetal strip and short-circuit protection via a magnetic coil. The magnetic trip threshold is fixed at 5.8 A, so it clears hard faults fast while letting motor inrush pass. Phase failure sensitivity is built in per IEC 60947-4-1, so the breaker trips if one phase drops out — critical for preventing single-phasing damage on three-phase motors. IP20 finger-safe protection means it's suitable for enclosed panels where no washdown or dust ingress is expected. The IK04 impact rating handles incidental tool contact during commissioning. Power dissipation is 2.5 W per pole, so three poles total 7.5 W at rated current. Factor that into cabinet thermal calculations to avoid derating in a sealed enclosure. Approvals include UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN/IEC 60947-2 and 60947-4-1, so it is accepted in North American and European panels without additional certification work.","metaTitle":"Schneider Electric GV2P03AE11 TeSys GV2 Motor Circuit Breake","metaDescription":"Schneider Electric GV2P03AE11 TeSys GV2 motor circuit breaker, 0.4 A rated current, 100 kA breaking capacity at 400 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"97 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws)","Control type":"Rotary handle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.09 kW at 400/415 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2P","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.4 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"5.8 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC front","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.25...0.4 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.4 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6c8aac58b27fed31b3a28195f60a0a07.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2P03AE11/motor-circuit-breaker-tesys-deca-3p-0-250-4-a-thermal-magnetic-screw-clamp-terminals-with-gvae11/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P03AE11/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to GV2P03AE11 in the TeSys GV2 family?","answer":"Within the TeSys GV2 range, the direct alternative is the same order code — there is no pin-compatible substitute with different ratings. For a different current rating, select the GV2Pxx variant matching your motor FLA."},{"question":"What compliance documentation does Schneider provide for GV2P03AE11?","answer":"The breaker carries UL, CSA, CE, and IEC certifications per the standards listed: UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-2, and EN/IEC 60947-4-1. Fire resistance is tested to 960 °C per IEC 60695-2-11."},{"question":"What is the depth of GV2P03AE11?","answer":"The depth is 97 mm, with a width of 45 mm and height of 89 mm. This fits standard DIN-rail enclosures with adequate clearance for wiring and the rotary handle."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P03AE11","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P03AE11 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}