{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P03TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P03TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2P03TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P03TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2P03TQ, 0.4 A rated current, 3-pole, thermal-magnetic trip, 100 kA breaking capacity at 400 V AC.","salesMarkdown":"Rated for motor duty at 0.09 kW at 400/415 V AC, this breaker is sized for small motors — fans, pumps, or conveyor drives — where the full-load current sits around 0.4 A. Horizontal or vertical orientation is allowed, so it fits tight layouts. Power connections accept up to 6 mm² solid or 4 mm² flexible with cable end. Tightening torque is 1.7 N·m on the screw clamp terminals — consistent with other TeSys GV2 sizes, so no special tooling required. Approvals include EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Also tested for glow-wire at 960 °C per IEC 60695-2-11 and for phase-failure sensitivity. These cover most industrial panels in North America and Europe without additional certification work. The magnetic trip threshold is 5.8 A — that's 14.5× In, which is typical for motor-start inrush on small IEC frames. If your motor's locked-rotor current exceeds that, the breaker may nuisance-trip on start; check the motor data against this curve. Electrical durability is 100,000 cycles at AC-3 duty (415 V, full load) — that's the standard for this class, not a premium rating. Mechanical durability matches at 100,000 cycles. For frequent switching applications (e.g., reversing starts), consider a contactor in series instead. Power dissipation is 2.5 W per pole, so 7.5 W total at rated current. The IP20 finger-safe front and IK04 impact resistance are standard for panel-mounted breakers; no washdown rating here.","metaTitle":"Schneider Electric GV2P03TQ TeSys GV2 Motor Circuit Breaker,","metaDescription":"Schneider Electric GV2P03TQ TeSys GV2 motor circuit breaker, 0.4 A rated current, 100 kA breaking capacity at 400 V AC. Current lifecycle stage. UL/CSA/IEC certified. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"97 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws)","Control type":"Rotary handle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.09 kW at 400/415 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2P","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.4 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"5.8 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.25...0.4 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.4 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/89664434529acebc0be0a714dd30c704.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2P03TQ/motor-circuit-breaker-tesys-deca-3p-0-25-to-0-4a-thermal-magneticc-screw-clamp-terminals-tq-24-units/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P03TQ/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this part carry?","answer":"It is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. It also meets glow-wire test at 960 °C and phase-failure sensitivity requirements."},{"question":"What is the closest alternative in the TeSys GV2 family?","answer":"The GV2P03TQ is the 0.4 A variant in the TeSys GV2 range. The closest peer is the GV2P04TQ (0.63 A) or GV2P05TQ (1 A) — same frame size, same breaking capacity, same mounting. The only difference is the thermal trip rating and magnetic threshold. No pin-compatible drop-in exists at a different current; you must select the rating matching your motor FLA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P03TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P03TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}