{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P05TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P05TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2P05TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P05TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2P05TQ, 3-pole, 1 A rated current, 0.25 kW at 400/415 V AC, thermal-magnetic trip, 100 kA breaking capacity.","salesMarkdown":"It protects a 0.25 kW motor at 400/415 V AC (0.55 kW at 690 V AC) and is sized for the smallest fractional-horsepower drives in a control panel — think small conveyors, fans, or pump starters on a BOM. The 1 A rating means it sits at the low end of the GV2 family, so verify your motor FLA matches before committing the line item. The magnetic trip is set at 15.1 A, which provides short-circuit protection while avoiding nuisance trips on motor inrush. Phase failure sensitivity is built in per IEC 60947-4-1, so the breaker will drop the load if one phase is lost — a standard requirement for motor protection in most industrial specs. ## Breaking capacity and standards compliance The GV2P05TQ carries a 100 kA Icu breaking capacity at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC — that is a flat 100 kA across the entire voltage range, not a derated curve. The part is certified to EN/IEC 60947-2 (circuit breakers), EN/IEC 60947-4-1 (contactors and motor-starters), UL 60947-4-1, and CSA C22.2 No 60947-4-1, so it qualifies for both IEC and North American panels. It also meets IEC/EN 60335-2-40 (heat pump and air-conditioning safety) and IEC/EN 60335-1 Clause 30.2 (glow-wire test at 960 °C per IEC 60695-2-11), which matters for appliance and HVAC OEMs that need the breaker in the end-product BOM. The 45 mm width (3-module) fits standard DIN-rail enclosures; the 89 mm height and 97 mm depth leave room for wiring ducts above and below. The rotary handle control is front-accessible, so the breaker can be manually tripped or reset with the panel door closed — a practical detail for maintenance techs who need to reset a tripped motor without opening the enclosure. Power connections accept up to two 6 mm² solid or 4 mm² flexible conductors per terminal, with a tightening torque of 1.7 N·m. The screw-clamp terminals are standard for panel wiring; no special tooling needed.","metaTitle":"Schneider GV2P05TQ TeSys GV2 Motor Circuit Breaker, 1 A, 0.2","metaDescription":"Schneider Electric GV2P05TQ TeSys GV2 motor circuit breaker, 1 A rated current, 0.25 kW at 400/415 V AC. Thermal-magnetic trip, 100 kA breaking capacity. Current lifecycle status.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"97 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws)","Control type":"Rotary handle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.25 kW at 400/415 V AC 50/60 Hz 0.55 kW at 690 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2P","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"1 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"15.1 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.63...1 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"1 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4a1d1957b4271781d2c81b9163f1d9de.pdf","sourceUrl":"https://www.se.com/be/en/product/GV2P05TQ/motor-circuit-breaker-tesys-deca-3p-0-631-a-thermal-magneticc-screw-clamp-terminals-tq-24-units/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P05TQ/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the GV2P05TQ?","answer":"The GV2P05TQ is a 3-pole motor circuit breaker rated at 1 A continuous current, with a magnetic trip at 15.1 A. It protects a 0.25 kW motor at 400/415 V AC and has a 100 kA Icu breaking capacity across the full voltage range up to 690 V AC."},{"question":"What standards does the GV2P05TQ comply with?","answer":"It is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and meets IEC/EN 60335-2-40 and IEC/EN 60335-1 Clause 30.2 for glow-wire resistance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P05TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P05TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}