{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P07KD09G7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P07KD09G7","canonicalUrl":"https://aoctrl.com/schneider/GV2P07KD09G7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P07KD09G7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2P07KD09G7, motor starter, 2.5 A rated current, 100 kA breaking capacity at 400 V, 3-pole, direct on-line contactor.","salesMarkdown":"The Schneider Electric TeSys GV2P07KD09G7 is a 3-pole motor starter combining a contactor and thermal-magnetic overload relay in one compact unit, rated for 2.5 A line current. It's designed for direct on-line starting of three-phase motors up to 0.75 kW at 400/415 V AC, 1.1 kW at 500 V, or 1.5 kW at 690 V. The 2.5 A rated current is the continuous thermal current (IEC 60947-4-1) — this governs the motor FLA it can carry without nuisance tripping. The magnetic trip is set at 33.5 A, so short-circuit protection clears fast on a locked-rotor or phase-to-phase fault. Utilisation categories AC-3 (squirrel-cage motors), AC-4 (plugging/inching), and AC-1 (resistive) cover the common motor-control duties; the 100,000-cycle electrical durability at AC-3 440 V gives a realistic service life for a production line running one start per minute over two shifts. The 45 mm width (1.8 in) fits a standard 45 mm slot in a TeSys GV2 busbar or distribution block. IP20 finger-safe terminals (IEC 60529) mean it's safe for open-panel installation where only qualified personnel access the enclosure. Screw-clamp terminals accept 1 to 6 mm² solid or 1.5 to 6 mm² flexible wire; torque to 1.7 N·m. Certified to UL 508, CSA C22.2, IEC 60947-2, IEC 60947-4-1, and EN 60204. The V1 flame retardance (UL 94) and 850 °C glow-wire resistance (IEC 60695-2-1) satisfy the fire-safety requirements for panel components in most industrial and commercial installations.","metaTitle":"Schneider TeSys GV2P07KD09G7 Motor Starter, 2.5 A, 100 kA Br","metaDescription":"Schneider Electric TeSys GV2P07KD09G7 motor starter, 2.5 A rated current, 100 kA breaking capacity at 400 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"3.8 in (97 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US10I1122368","Standards":"VDE 0113 CSA C22.2 EN 60204 IEC 60947-2 IEC 60947-4-1 NF C 79-130 NF C 63-120 NF C 63-650 VDE 0660 UL 508 IEC 60947-1","Rated duty":"Continuous IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with 2 x M4 screws)","Control Type":"Rotary knob","Motor power kW":"0.75 kW 400/415 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 1.5 kW 690 V AC 50/60 Hz","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Direct connector":"Without","Flame retardance":"V1 conforming to UL 94","Pollution degree":"3","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 8 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Motor Power Range":"0...0.5 kW 100...120 V 3 phase 0.55...1 kW 100...120 V 3 phase 0...0.5 kW 200...240 V 3 phase 0.55...1 kW 200...240 V 3 phase 1.1...2 kW 200...240 V 3 phase 0...0.5 kW 380...440 V 3 phase 0.55...1 kW 380...440 V 3 phase 1.1...2 kW 380...440 V 3 phase 2.2...3 kW 380...440 V 3 phase 4...6 kW 380...440 V 3 phase 0...0.5 kW 480...500 V 3 phase 0.55...1 kW 480...500 V 3 phase 1.1...2 kW 480...500 V 3 phase 2.2...3 kW 480...500 V 3 phase 4...6 kW 480...500 V 3 phase 0...0.5 kW 525...690 V 3 phase 0.55...1 kW 525...690 V 3 phase 1.1...2 kW 525...690 V 3 phase 2.2...3 kW 525...690 V 3 phase 4...6 kW 525...690 V 3 phase","Network frequency":"50/60 Hz IEC 60947-4-1","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminals","Climatic withstand":"IACS E10","Line Rated Current":"2.5 A","Motor starter type":"Direct on-line contactor","Operating altitude":"6561.68 ft (2000 m)","Operating position":"Any position","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contact compatibility":"M2","Contactor application":"Resistive load Motor control","Electrical durability":"100000 cycles AC-3 440 V","Mechanical durability":"100000 cycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor open10 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"screw clamp terminals 2 0.002...0.009 in² (1...6 mm²) solid screw clamp terminals 2 0.002...0.009 in² (1.5...6 mm²) flexible without cable end screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"33.5 A","Product or Component Type":"Motor starter","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit Power circuit 10 MOhm for signalling circuit","Complementary/Utilisation category":"AC-3 IEC 60947-4-1 Category A IEC 60947-2","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for storage":"-40...176 °F (-40...80 °C)","Ambient Air Temperature for Operation":"23...140 °F (-5...60 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"2.5 A IEC 60947-4-1","Complementary/[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 690 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/38dd0ea5ae99e064bd239cc5297f2486.pdf","sourceUrl":"https://www.se.com/us/en/product/GV2P07KD09G7/motor-starter-kit-tesys-lc1d09g7-contactor-gv2p07-motor-starter-protector-120-vac-50-60-hz-coil-1-6-to-2-5a-trip/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P07KD09G7/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity at 400 V?","answer":"100 kA Icu at 400/415 V AC 50/60 Hz per IEC 60947-2."},{"question":"What motor power does this cover at 400 V?","answer":"0.75 kW at 400/415 V AC, 1.1 kW at 500 V, and 1.5 kW at 690 V."},{"question":"What approvals does it carry?","answer":"UL 508, CSA C22.2, IEC 60947-2, IEC 60947-4-1, EN 60204, and VDE 0660."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P07KD09G7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P07KD09G7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}