{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P14KD09B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P14KD09B7","canonicalUrl":"https://aoctrl.com/schneider/GV2P14KD09B7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P14KD09B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2P14KD09B7, motor starter, 3-pole, 10 A line rated current, 100 kA breaking capacity at 400 V AC, 24 V AC coil, DIN rail mount.","salesMarkdown":"## Part identification and key ratings The Schneider Electric TeSys GV2P14KD09B7 is a direct on-line motor starter combining a 3-pole circuit breaker and a contactor in one unit, rated for a line current of 10 A. It is designed for motor control applications across utilisation categories AC-1 (resistive), AC-3 (squirrel-cage motor starting/stopping), and AC-4 (plugging/inching). Motor power capability spans 2.2 to 3 kW at 380 to 440 V three-phase, and 4 to 6 kW at 480 to 500 V three-phase, with a 24 V AC control coil. This motor starter holds compliance with IEC 60947-2, IEC 60947-4-1, UL 508, CSA C22.2, VDE 0660, and EN 60204, covering overcurrent protection and motor controller requirements for North American and European installations. Pollution degree 3 rating suits industrial environments with conductive contamination. IP20 finger-safe protection is provided per IEC 60529. Screw clamp terminals accept 1 to 6 mm² solid or stranded wire; tightening torque is 1.7 N·m. The rotary knob control allows manual on/off/reset without opening the enclosure. ## Durability and environmental withstand Rated for 100,000 electrical cycles under AC-3 at 440 V, and 100,000 mechanical cycles. Vibration resistance is 2 Gn (contactor open) and 4 Gn (closed) across 5 to 300 Hz; shock resistance is 10 Gn open and 15 Gn closed for 11 ms. Climatic withstand per IACS and protective treatment TH for tropical environments. Fire resistance tested to 850 °C per IEC 60695-2-1, with flame retardance V1 per UL 94.","metaTitle":"Schneider Electric GV2P14KD09B7 TeSys Motor Starter, 10 A, 1","metaDescription":"Schneider Electric TeSys GV2P14KD09B7 motor starter, 10 A line rated current, 100 kA breaking capacity at 400 V AC. IEC 60947-2, UL 508 compliant. Active production. Sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"3.8 in (97 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US10I1122368","Standards":"IEC 60947-2 UL 508 VDE 0113 NF C 79-130 NF C 63-650 IEC 60947-1 CSA C22.2 NF C 63-120 IEC 60947-4-1 VDE 0660 EN 60204","Rated duty":"Continuous IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with 2 x M4 screws)","Control Type":"Rotary knob","Motor power kW":"3 kW 400/415 V AC 50/60 Hz 5.5 kW 690 V AC 50/60 Hz 5 kW 500 V AC 50/60 Hz","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Direct connector":"Without","Flame retardance":"V1 conforming to UL 94","Pollution degree":"3","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Motor Power Range":"1.1...2 kW 200...240 V 3 phase 2.2...3 kW 380...440 V 3 phase 4...6 kW 380...440 V 3 phase 4...6 kW 480...500 V 3 phase","Network frequency":"50/60 Hz IEC 60947-4-1","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminals","Climatic withstand":"IACS E10","Line Rated Current":"10 A","Motor starter type":"Direct on-line contactor","Operating altitude":"6561.68 ft (2000 m)","Operating position":"Any position","Protective treatment":"TH","Utilisation category":"AC-4 AC-1 AC-3","Contact compatibility":"M2","Contactor application":"Resistive load Motor control","Electrical durability":"100000 cycles AC-3 440 V","Mechanical durability":"100000 cycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor open10 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms","Nbr. of units in pkg.":"1","Contactor coil voltage":"24 V AC standard","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"screw clamp terminals 2 0.002...0.009 in² (1...6 mm²) solid screw clamp terminals 2 0.002...0.009 in² (1.5...6 mm²) flexible without cable end screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"138 A","Product or Component Type":"Motor starter","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit Power circuit 10 MOhm for signalling circuit","Complementary/Utilisation category":"AC-3 IEC 60947-4-1 Category A IEC 60947-2","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for storage":"-40...176 °F (-40...80 °C)","Ambient Air Temperature for Operation":"23...140 °F (-5...60 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"10 A IEC 60947-4-1","Complementary/[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 690 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8c3d4b973da617ce81927a3b975bb3c1.pdf","sourceUrl":"https://www.se.com/us/en/product/GV2P14KD09B7/motor-starter-kit-tesys-lc1d09b7-contactor-gv2p14-motor-starter-protector-24-vac-50-60-hz-coil-6-to-10a-trip/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P14KD09B7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this motor starter?","answer":"Line rated current is 10 A, breaking capacity is 100 kA Icu at 400/415 V AC per IEC 60947-2, and it covers motor power from 2.2 to 6 kW depending on supply voltage. The control coil is 24 V AC."},{"question":"What standards does GV2P14KD09B7 comply with?","answer":"It complies with IEC 60947-2, IEC 60947-4-1, UL 508, CSA C22.2, VDE 0660, EN 60204, and related standards for overcurrent protection and motor control."},{"question":"How is this motor starter mounted?","answer":"It clips onto a 35 mm symmetrical DIN rail or can be panel-mounted with two M4 screws. Dimensions are 89 x 45 x 97 mm (H x W x D)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P14KD09B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P14KD09B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}