{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2P20KD25BL","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2P20KD25BL","canonicalUrl":"https://aoctrl.com/schneider/GV2P20KD25BL","factsUrl":"https://aoctrl.com/api/mcp/products/GV2P20KD25BL","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2P20KD25BL motor starter, 3-pole, 18 A line rated current, 24 V DC low consumption coil, IP20, DIN-rail mount.","salesMarkdown":"The Schneider Electric TeSys GV2P20KD25BL is a direct on-line motor starter combining a contactor and thermal-magnetic overload relay in a single 3-pole package. It is rated for continuous duty per IEC 60947-4-1 and carries a line rated current of 18 A. The IP20 degree of protection means it is suited for installation inside a cabinet, not exposed to washdown. It is designed for motor control and resistive loads, with utilisation categories AC-1, AC-3, and AC-4 covering resistive, squirrel-cage motor starting, and plugging/inching duties respectively. The breaking capacity (Icu) per IEC 60947-2 is 100 kA at 230/240 V AC, 50 kA at 400/415 V AC, 20 kA at 440 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. The magnetic tripping current is set at 223 A, providing short-circuit protection for the motor branch circuit. The 18 A line rated current sets the continuous ampacity for the thermal overload element. The control coil is 24 V DC low consumption, which is a common safety voltage for control circuits and reduces heat dissipation inside the panel compared to AC coils. ## Standards Compliance and Lifecycle This motor starter complies with UL 508, IEC 60947-1, IEC 60947-2, IEC 60947-4-1, CSA C22.2, and EN 60204, among others. This means it is accepted for use in North American and European installations without additional certification hurdles.","metaTitle":"Schneider TeSys GV2P20KD25BL Motor Starter, 18 A, 3P","metaDescription":"Schneider Electric TeSys GV2P20KD25BL motor starter, 18 A line current, 3-pole, 24 VDC coil. UL 508, IEC 60947. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"3.8 in (97 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US10I1122368","Standards":"UL 508 IEC 60947-1 IEC 60947-2 EN 60204 NF C 79-130 NF C 63-120 NF C 63-650 IEC 60947-4-1 CSA C22.2 VDE 0113 VDE 0660","Rated duty":"Continuous IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with 2 x M4 screws)","Control Type":"Rotary knob","Motor power kW":"7.5 kW 400/415 V AC 50/60 Hz 9 kW 500 V AC 50/60 Hz 15 kW 690 V AC 50/60 Hz","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Direct connector":"Without","Flame retardance":"V1 conforming to UL 94","Pollution degree":"3","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 4 kA Icu 690 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2","Motor Power Range":"4...6 kW 200...240 V 3 phase 7...11 kW 380...440 V 3 phase 7...11 kW 480...500 V 3 phase","Network frequency":"50/60 Hz IEC 60947-4-1","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminals","Climatic withstand":"IACS E10","Line Rated Current":"18 A","Motor starter type":"Direct on-line contactor","Operating altitude":"6561.68 ft (2000 m)","Operating position":"Any position","Protective treatment":"TH","Utilisation category":"AC-4 AC-3 AC-1","Contact compatibility":"M5","Contactor application":"Motor control Resistive load","Electrical durability":"100000 cycles AC-3 440 V","Mechanical durability":"100000 cycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Shocks contactor open8 Gn for 11 ms","Nbr. of units in pkg.":"1","Contactor coil voltage":"24 V DC low consumption","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"screw clamp terminals 2 0.002...0.009 in² (1...6 mm²) solid screw clamp terminals 2 0.002...0.009 in² (1.5...6 mm²) flexible without cable end screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"223 A","Product or Component Type":"Motor starter","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit Power circuit 10 MOhm for signalling circuit","Complementary/Utilisation category":"AC-3 IEC 60947-4-1 Category A IEC 60947-2","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for storage":"-40...176 °F (-40...80 °C)","Ambient Air Temperature for Operation":"23...140 °F (-5...60 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"18 A IEC 60947-4-1","Complementary/[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 690 V AC 50/60 Hz IEC 60947-2 100 % 230/240 V AC 50/60 Hz IEC 60947-2 75 % 500 V AC 50/60 Hz IEC 60947-2 50 % 400/415 V AC 50/60 Hz IEC 60947-2 75 % 440 V AC 50/60 Hz IEC 60947-2","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ae0147fcaae76b76254258b5bb2c2199.pdf","sourceUrl":"https://www.se.com/us/en/product/GV2P20KD25BL/motor-starter-kit-tesys-lc1d25bl-contactor-gv2p20-motor-starter-protector-24-vdc-coil-13-to-18a-trip/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2P20KD25BL/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel layout?","answer":"The GV2P20KD25BL has a depth of 3.8 in (97 mm), a width of 1.8 in (45 mm), and a height of 3.5 in (89 mm)."},{"question":"What compliance documentation is available for this part?","answer":"The GV2P20KD25BL is certified to UL 508, IEC 60947-1, IEC 60947-2, IEC 60947-4-1, CSA C22.2, EN 60204, and several other national standards. The manufacturer provides declarations of conformity and certificates for these standards."},{"question":"What is the closest alternative to the GV2P20KD25BL in the TeSys range?","answer":"Within the TeSys range, the closest alternative would be a model with the same frame size and similar ratings but possibly a different coil voltage or auxiliary contact configuration. For a direct replacement, verify the line rated current (18 A) and coil voltage (24 V DC) match your BOM."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2P20KD25BL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2P20KD25BL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}