{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT03AE11TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT03AE11TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2RT03AE11TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT03AE11TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2RT03AE11TQ, 0.4 A rated current, thermal-magnetic trip, 3-pole, 100 kA breaking capacity, screw clamp terminals, 1 NO + 1 NC auxiliary contacts.","salesMarkdown":"The GV2RT03AE11TQ is a TeSys GV2 motor circuit breaker from Schneider Electric's TeSys Deca range, rated at 0.4 A continuous current (In) with a thermal-magnetic trip unit. That 0.4 A is the continuous rating that governs the motor protection curve — it's sized for a 0.06 kW motor at 230 V or 0.09 kW at 400 V, so the breaker's thermal element tracks the motor's heating characteristic, not just a generic branch circuit. The magnetic trip is set at 8 A, so the instantaneous short-circuit pickup is 20× the thermal rating. This is typical for motor-starting inrush. Breaking capacity is a flat 100 kA Icu across the voltage range from 230 V to 690 V AC, certified to IEC 60947-2. The 78.5 mm depth leaves clearance in a standard enclosure. The front-mounted toggle provides manual on/off control and a trip-indicated position. The auxiliary contact block — 1 NO + 1 NC — is integrated into the front, so you get a remote status signal without an add-on module, useful for a PLC input or a seal-in circuit. The 100 000-cycle electrical durability at AC-3 and AC-3e duty (at 415 V, full rated current) and matching mechanical endurance mean this breaker is rated for the life of a typical conveyor or pump motor in a production line — not a one-shot device. Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor-starter standard for motor protection), with suitability for isolation per IEC 60947-1. Climatic withstand conforms to IACS for marine environments, and the 960 °C glow-wire test per IEC 60695-2-11 covers fire resistance in the panel.","metaTitle":"Schneider GV2RT03AE11TQ TeSys GV2 Motor Circuit Breaker, 0.4","metaDescription":"Schneider Electric GV2RT03AE11TQ TeSys GV2 motor circuit breaker, 0.4 A rated current, thermal-magnetic trip, 100 kA breaking capacity. Active production, sourced to order. EN/IEC","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.06 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.09 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.09 kW at 440 V AC 50/60 Hz motor protection high peak current 0.12 kW at 440 V AC 50/60 Hz motor protection high peak current","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection Transformer","Operating altitude":"<= 2000 m","[In] rated current":"0.4 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"8 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC front","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.25...0.4 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.4 A conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/08be0b2e8bbe904ee76a9f00e29d83c1.pdf","sourceUrl":"https://www.se.com/be/en/product/GV2RT03AE11TQ/motor-circuit-breaker-tesys-deca-3p-0-250-4-a-thermal-magnetic-screw-clamp-terminals-with-gvae11-tq-24-units/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT03AE11TQ/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the GV2RT03AE11TQ in the TeSys GV2 family?","answer":"The standard single-unit order code GV2RT03 is the same breaker without the bulk-pack quantity (set of 24). The electrical ratings — 0.4 A In, 8 A magnetic trip, 100 kA breaking capacity — are identical. The choice is purely packaging: the AE11TQ suffix denotes the 24-piece tray, which matters only if you're filling a BOM line for multiple panels."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, with suitability for isolation per IEC 60947-1. Climatic withstand conforms to IACS (marine). The fire-resistance rating is 960 °C per IEC 60695-2-11."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT03AE11TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT03AE11TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}