{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT063","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT063","canonicalUrl":"https://aoctrl.com/schneider/GV2RT063","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT063","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2RT063, 3-pole motor circuit breaker, thermal-magnetic, 1.6 A rated current, 100 kA breaking capacity at 400 V, spring terminals, DIN rail mount.","salesMarkdown":"The Schneider Electric GV2RT063 is a TeSys Deca GV2 motor circuit breaker — a 3-pole thermal-magnetic device rated 1.6 A continuous, with an adjustable thermal protection range of 1...1.6 A. It's built to protect motor and transformer loads per IEC 60947-2 and IEC 60947-4-1, with a 100 kA interrupting capacity at 400 V AC that holds all the way to 690 V. The thermal-magnetic trip unit handles both overload (thermal) and short-circuit (magnetic) events. The magnetic trip is fixed at 33 A, so it rides through motor inrush without nuisance tripping but still clears a hard fault fast. Rated for AC-3 and AC-3e duty categories, meaning it's certified for switching squirrel-cage motors under load — the most common motor-starting regime in industrial panels. ## Mounting and wiring — panel fit At 45 mm wide and 89 mm tall, it fits standard motor-starter footprints in a control cabinet. The spring-cage terminals on the power circuit accept 1...6 mm² solid or 1.5...4 mm² flexible with ferrule — two conductors per terminal, so daisy-chaining the line side is straightforward. No screw torque to verify; the spring holds the conductor captive. Rated IP20 finger-safe on the front, IK04 impact resistance. The 78.5 mm depth leaves clearance behind a standard 100 mm deep enclosure door. Ambient operating range is -20 to 60 °C, storage -40 to 80 °C, with a fire-resistance rating of 960 °C per IEC 60695-2-11. Suitable for isolation per IEC 60947-1 — you can lock it off for downstream work. ## Motor power coverage At 1.6 A thermal setting, this breaker covers small motors: 0.37 kW at 400/415 V AC (high peak current motor protection), 0.55 kW at 500 V, and up to 1.1 kW at 690 V. For transformer protection, it covers 0.63 kVA at 400/415 V. The power dissipation per pole is 2.5 W — about 7.5 W total at full load, which matters for thermal rise in a densely packed DIN-rail row.","metaTitle":"Schneider Electric GV2RT063 TeSys GV2 Motor Circuit Breaker,","metaDescription":"Schneider Electric GV2RT063 TeSys Deca motor circuit breaker, 1.6 A rated current, 100 kA breaking capacity at 400 V. Thermal-magnetic trip, spring terminals, DIN rail mount. Activ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.18 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.25 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.37 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.55 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.37 kW at 440 V AC 50/60 Hz motor protection high peak current 0.55 kW at 440 V AC 50/60 Hz motor protection high peak current 0.37 kW at 500 V AC 50/60 Hz motor protection high peak current 0.55 kW at 500 V AC 50/60 Hz motor protection high peak current 0.75 kW at 500 V AC 50/60 Hz motor protection high peak current 0.75 kW at 690 V AC 50/60 Hz motor protection high peak current 1.1 kW at 690 V AC 50/60 Hz motor protection high peak current 0.4 kW at 230/240 V AC 50/60 Hz transformer protection 0.63 kW at 400/415 V AC 50/60 Hz transformer protection 1 kW at 440 V AC 50/60 Hz transformer protection 1 kW at 500 V AC 50/60 Hz transformer protection","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection Transformer","Operating altitude":"<= 2000 m","[In] rated current":"1.6 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: spring terminals 2 cable(s) 1...6 mm²solid Power circuit: spring terminals 2 cable(s) 1.5...4 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"33 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"1...1.6 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"1.6 A conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6f401ba7ee74e89563a7b27deac8e1ad.pdf","sourceUrl":"https://www.se.com/be/en/product/GV2RT063/motor-circuit-breakertesys-deca3p11-6athermal-magneticspring-terminalstoggle-handle/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT063/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the GV2RT063?","answer":"The GV2RT063 has a 100 kA Icu breaking capacity at 220/230 V, 400/415 V, 440 V, 500 V, and 690 V AC per IEC 60947-2. That's a high-interrupting rating that holds across the voltage range, so it clears faults without upstream fuses needing to operate in most panel configurations."},{"question":"What wire sizes does the spring terminal accept?","answer":"The power circuit spring terminals accept 1...6 mm² solid wire, or 1.5...4 mm² flexible without ferrule, or 1...4 mm² flexible with ferrule. Two conductors per terminal are allowed, which simplifies daisy-chaining the line side in a motor starter group."},{"question":"What compliance documentation does Schneider provide for the GV2RT063?","answer":"The GV2RT063 is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, with a suitability-for-isolation marking per IEC 60947-1. The climatic withstand conforms to IACS. Standard Schneider documentation includes the declaration of conformity, CE marking, and UL/CSA file numbers available through the Schneider portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT063","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT063 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}