{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT06AE11TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT06AE11TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2RT06AE11TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT06AE11TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2RT06AE11TQ, motor circuit breaker, 3-pole, 1.6 A rated current, thermal-magnetic trip, 100 kA breaking capacity, 1 NO + 1 NC auxiliary contacts.","salesMarkdown":"The Schneider Electric GV2RT06AE11TQ is a TeSys Deca GV2RT series motor circuit breaker, 3-pole, rated 1.6 A with a thermal-magnetic trip unit. The 1.6 A rating means this breaker protects small motors — it covers motor power from 0.18 kW at 230 V up to 1.1 kW at 690 V, depending on the supply voltage and whether it's motor or transformer duty. The thermal-magnetic trip gives both overload (thermal) and short-circuit (magnetic) protection in one device. That's useful for panels with high available fault current. Accepts horizontal or vertical orientation. Power connections are screw-clamp terminals accepting up to 2 x 6 mm² solid or 2 x 4 mm² flexible with ferrule. The toggle control type gives manual on/off and trip-reset capability right on the front face. IK04 impact resistance handles incidental tool bumps during commissioning. It's part of the TeSys Deca family, a widely used motor protection platform with good cross-reference support. The GV2RT06AE11TQ is the 1.6 A variant with auxiliary contacts included — the base GV2RT06 without the 'TQ' suffix omits the aux contacts. ## Key ratings in context Magnetic trip threshold is 33 A, about 20x the In, giving good short-circuit discrimination for motor starting inrush. Electrical durability is 100,000 cycles at AC-3 duty (415 V at rated current), matching the mechanical durability of 100,000 cycles. Power dissipation is 2.5 W per pole — 7.5 W total at full load, manageable in a standard enclosure. Climatic withstand conforms to IACS for marine and humid environments.","metaTitle":"TeSys GV2RT06AE11TQ Motor Circuit Breaker, 1.6 A, 100 kA","metaDescription":"Schneider TeSys GV2RT06AE11TQ motor circuit breaker, 1.6 A rated current, 100 kA breaking capacity at 400 V. EN/IEC 60947-2 and 4-1. Active production. DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.18 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.25 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.37 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.55 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.37 kW at 440 V AC 50/60 Hz motor protection high peak current 0.55 kW at 440 V AC 50/60 Hz motor protection high peak current 0.37 kW at 500 V AC 50/60 Hz motor protection high peak current 0.55 kW at 500 V AC 50/60 Hz motor protection high peak current 0.75 kW at 500 V AC 50/60 Hz motor protection high peak current 0.75 kW at 690 V AC 50/60 Hz motor protection high peak current 1.1 kW at 690 V AC 50/60 Hz motor protection high peak current 0.4 kW at 230/240 V AC 50/60 Hz transformer protection 0.63 kW at 400/415 V AC 50/60 Hz transformer protection 1 kW at 440 V AC 50/60 Hz transformer protection 1 kW at 500 V AC 50/60 Hz transformer protection","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection Transformer","Operating altitude":"<= 2000 m","[In] rated current":"1.6 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"33 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC front","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"1...1.6 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"1.6 A conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b64a4c71abf17884ec1be39fa614d0be.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2RT06AE11TQ/motor-circuit-breakertesys-deca-frame-23p11-6athermal-magnetictoggle-controlscrew-clamp-terminalswith-gvae11bulk-qty/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT06AE11TQ/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of GV2RT06AE11TQ?","answer":"100 kA Icu at all rated voltages from 230 V to 690 V AC, conforming to IEC 60947-2. That's consistent across the full voltage range, not just at one voltage."},{"question":"What auxiliary contacts does this breaker include?","answer":"It includes 1 normally-open and 1 normally-closed front-mounted auxiliary contact. The 'TQ' suffix in the order code indicates these are factory-fitted."},{"question":"What standards does GV2RT06AE11TQ comply with?","answer":"It conforms to EN/IEC 60947-2 for circuit-breaker performance and EN/IEC 60947-4-1 for motor-starter coordination. It also meets IEC 60695-2-11 glow-wire test at 960 °C and is suitable for isolation per IEC 60947-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT06AE11TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT06AE11TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}