{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT07","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT07","canonicalUrl":"https://aoctrl.com/schneider/GV2RT07","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT07","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys Deca motor circuit breaker, GV2RT07, 3-pole, 2.5 A rated current, thermal-magnetic trip, 100 kA breaking capacity, IP20, DIN rail mount.","salesMarkdown":"## Motor Protection with a Fault Capacity that Matches the Line The GV2RT07 is a 3-pole thermal-magnetic motor circuit breaker from the TeSys Deca range, rated 2.5 A continuous. It's built for motor starter duty: AC-3 switching and full isolation per IEC 60947-1. The thermal trip handles long-term overloads; the magnetic trip snaps at 51 A for short-circuit protection. That 51 A threshold is fixed – no adjustment – so make sure your motor's inrush won't nuisance-trip it. On a typical 0.37 kW, 230 V motor that's fine; for a higher-inrush pump motor you'd step to a bigger frame. The 100 kA Icu holds up to 440 V, then drops to 3 kA at 690 V. That matters if your plant runs a 690 V motor line – the breaker still protects, but the available fault current must be under 3 kA. ## Mounting and Wire-Up Accepts 1 to 6 mm² solid or stranded wire on the screw clamps – torque to 1.7 N·m. IP20 means it's protected from finger contact but not hose-down; mount inside a panel or enclosure.","metaTitle":"Schneider TeSys Deca GV2RT07 Motor Circuit Breaker, 2.5 A","metaDescription":"Active motor circuit breaker, 3P, 2.5 A, thermal-magnetic, 100 kA breaking capacity up to 440 V. IP20, DIN rail. Comply with EN/IEC 60947.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.09 in (78.5 mm)","Range":"TeSys Deca","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US10I1122367","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)","Control Type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.37 kW 220/230 V AC 50/60 Hz motor protection high peak current 0.75 kW 400/415 V AC 50/60 Hz motor protection high peak current 0.75 kW 440 V AC 50/60 Hz motor protection high peak current 1.1 kW 440 V AC 50/60 Hz motor protection high peak current 1.1 kW 500 V AC 50/60 Hz motor protection high peak current 1.5 kW 690 V AC 50/60 Hz motor protection high peak current 0.63 kW 230/240 V AC 50/60 Hz transformer protection 1 kW 400/415 V AC 50/60 Hz transformer protection 1.6 kW 500 V AC 50/60 Hz transformer protection 1.6 kW 690 V AC 50/60 Hz transformer protection 2 kW 690 V AC 50/60 Hz transformer protection","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminal","Climatic withstand":"IACS E10","Device Application":"Motor protection Transformer","Line Rated Current":"2.5 A","Operating altitude":"<= 6561.68 ft (2000 m)","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1","Electrical durability":"100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks 30 Gn for 11 ms Vibrations 5 Gn, 5...150 Hz","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit screw clamp terminal 2 0.002...0.009 in² (1...6 mm²)solid Power circuit screw clamp terminal 2 0.002...0.009 in² (1.5...6 mm²)flexible without cable end Power circuit screw clamp terminal 2 0.002...0.006 in² (1...4 mm²)flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"51 A","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Thermal protection adjustment range":"1.6...2.5 A IEC 60947-2","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"2.5 A IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.09","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/374b4183068226eb65a40123574d7942.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT07/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the GV2RT07?","answer":"The depth is 3.09 inches (78.5 mm)."},{"question":"What compliance documentation does the GV2RT07 carry?","answer":"It complies with EN/IEC 60947-2 and 60947-4-1, IP20 per IEC 60529, and has a fire resistance of 960 °C per IEC 60695-2-11."},{"question":"What is the rated operational voltage for the GV2RT07?","answer":"Rated operational voltage (Ue) is 690 V AC at 50/60 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT07","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT07 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}