{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT073","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT073","canonicalUrl":"https://aoctrl.com/schneider/GV2RT073","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT073","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2RT073 motor circuit breaker, 3-pole, thermal-magnetic, 2.5 A rated current, 100 kA breaking capacity at 400 V AC.","salesMarkdown":"It uses a thermal-magnetic trip unit — the thermal element handles overloads, and the magnetic element (fixed at 51 A) clears short-circuits. The thermal protection adjustment range is 1.6...2.5 A, so you set the dial to match the motor's full-load current. At the 2.5 A setting, this breaker covers motors rated 0.37 kW at 230 V or 0.75 kW at 400 V. The AC-3 utilisation category confirms it's rated for switching squirrel-cage motors — starting and stopping under load — with 100,000 electrical cycles at rated current. The 690 V rated insulation voltage and 6 kV impulse withstand voltage mean it's suitable for 400 V line-to-line systems with adequate margin. Snaps onto 35 mm symmetrical DIN rail, or screws to a panel with an adaptor plate. The 45 mm width takes one standard modular slot. Spring-cage terminals on the power circuit accept 1...6 mm² solid or 1...4 mm² flexible with ferrule — no screw torque to verify, which speeds panel wiring. Mount horizontally or vertically; the IP20 finger-safe enclosure suits enclosed panels, not washdown zones. Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor-starter standard), so it qualifies as both a branch-circuit protective device and a motor-protective device. It's also suitability for isolation per IEC 60947-1 — meaning you can safely use the toggle as a visible disconnect. Climatic withstand per IACS covers marine and humid environments.","metaTitle":"Schneider Electric GV2RT073 TeSys Deca Motor Circuit Breaker","metaDescription":"Schneider Electric GV2RT073 TeSys Deca motor circuit breaker, 2.5 A rated current, thermal-magnetic trip, 100 kA breaking capacity at 400 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.37 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.75 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.75 kW at 440 V AC 50/60 Hz motor protection high peak current 1.1 kW at 440 V AC 50/60 Hz motor protection high peak current 1.1 kW at 500 V AC 50/60 Hz motor protection high peak current 1.5 kW at 690 V AC 50/60 Hz motor protection high peak current 0.63 kW at 230/240 V AC 50/60 Hz transformer protection 1 kW at 400/415 V AC 50/60 Hz transformer protection 1.6 kW at 500 V AC 50/60 Hz transformer protection 1.6 kW at 690 V AC 50/60 Hz transformer protection 2 kW at 690 V AC 50/60 Hz transformer protection","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection Transformer","Operating altitude":"<= 2000 m","[In] rated current":"2.5 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: spring terminals 2 cable(s) 1...6 mm²solid Power circuit: spring terminals 2 cable(s) 1.5...4 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"51 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"1.6...2.5 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"2.5 A conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/018f9c80d016b024afd10d3b98c1955a.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2RT073/motor-circuit-breakertesys-deca3p1-62-5athermal-magneticspring-terminalstoggle-handle/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT073/alternatives.json"},"ai":{"faq":[{"question":"What is the thermal adjustment range on this breaker?","answer":"The thermal protection adjustment range is 1.6 to 2.5 A. Set the dial to match the motor's full-load current within that window."},{"question":"What breaking capacity does it have at 400 V?","answer":"100 kA Icu at 400/415 V AC, 50/60 Hz, per IEC 60947-2. This is the maximum short-circuit current it can safely interrupt at that voltage level."},{"question":"What motor sizes does the 2.5 A setting cover?","answer":"At the 2.5 A setting, it covers a 0.37 kW motor at 230 V or a 0.75 kW motor at 400 V, both for motor protection with high peak current."},{"question":"Does it mount on DIN rail?","answer":"Yes, it clips onto 35 mm symmetrical DIN rail. It can also be panel-mounted with an adaptor plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT073","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT073 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}