{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT07AE11TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT07AE11TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2RT07AE11TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT07AE11TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2RT07AE11TQ, motor circuit breaker, 3-pole, 2.5 A rated current, thermal-magnetic, 100 kA breaking capacity at 400 V AC.","salesMarkdown":"It's designed for motor and transformer protection, with a magnetic tripping current of 51 A that clears short circuits fast enough to protect downstream contactors and cable runs. That's a high-interrupting rating for a compact 45 mm wide device — it handles most industrial supply transformers without needing a current-limiting upstream breaker. It carries motor power ratings from 0.37 kW at 230 V up to 1.5 kW at 690 V, and transformer protection ratings up to 2 kW at 690 V. The utilisation category is AC-3 and AC-3e per IEC 60947-4-1, so it's rated for starting and stopping squirrel-cage motors under load — not just resistive switching. It ships with 1 NO + 1 NC auxiliary contacts built into the front face, so you get status feedback without adding a separate aux block. Power connections accept up to 6 mm² solid or 4 mm² flexible with ferrule, torqued to 1.7 N·m. The IK04 impact rating means it survives the odd dropped tool during commissioning. The set quantity is 24 units, which matches the typical panel-builder batch for a multi-motor control cabinet. Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor/motor-starter standard), so it qualifies as both a branch-circuit protective device and a motor-protective device under IEC. Fire resistance tested to 960 °C per IEC 60695-2-11, and climatic withstand conforms to IACS for marine-environment humidity cycling. Operating altitude is limited to 2000 m without derating.","metaTitle":"Schneider TeSys GV2RT07AE11TQ Motor Circuit Breaker, 2.5 A,","metaDescription":"Schneider Electric TeSys GV2RT07AE11TQ motor circuit breaker, 2.5 A rated current, 3-pole, thermal-magnetic trip. 100 kA breaking capacity at 400 V. Active production. Sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.37 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.75 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.75 kW at 440 V AC 50/60 Hz motor protection high peak current 1.1 kW at 440 V AC 50/60 Hz motor protection high peak current 1.1 kW at 500 V AC 50/60 Hz motor protection high peak current 1.5 kW at 690 V AC 50/60 Hz motor protection high peak current 0.63 kW at 230/240 V AC 50/60 Hz transformer protection 1 kW at 400/415 V AC 50/60 Hz transformer protection 1.6 kW at 500 V AC 50/60 Hz transformer protection 1.6 kW at 690 V AC 50/60 Hz transformer protection 2 kW at 690 V AC 50/60 Hz transformer protection","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection Transformer","Operating altitude":"<= 2000 m","[In] rated current":"2.5 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"51 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC front","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"1.6...2.5 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"2.5 A conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2ca4279b4b0adaf99bbe7d78957408cd.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2RT07AE11TQ/motor-circuit-breakertesys-deca-frame-23p1-62-5athermal-magnetictoggle-controlscrew-clamp-terminalswith-gvae11bulk-qty/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT07AE11TQ/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this motor circuit breaker?","answer":"Rated current is 2.5 A with a magnetic trip at 51 A. Breaking capacity is 100 kA Icu at 400/415 V AC. Motor power ranges from 0.37 kW at 230 V to 1.5 kW at 690 V. It's a 3-pole thermal-magnetic device with 1 NO + 1 NC auxiliary contacts."},{"question":"What standards does the GV2RT07AE11TQ comply with?","answer":"It is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, and is suitable for isolation per IEC 60947-1. Climatic withstand conforms to IACS."},{"question":"How does the GV2RT07AE11TQ mount in a panel?","answer":"It clips onto a 35 mm symmetrical DIN rail or can be screwed to a panel using an adaptor plate. Width is 45 mm, fitting one modular space on the rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT07AE11TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT07AE11TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}