{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT083","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT083","canonicalUrl":"https://aoctrl.com/schneider/GV2RT083","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT083","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca motor circuit breaker, GV2RT083, thermal-magnetic, 3-pole, 4 A rated current, 100 kA breaking capacity at 400 V AC, spring terminals, DIN rail mount.","salesMarkdown":"The thermal adjustment range of 2.5...4 A means the overload element can be dialed to match the motor full-load current anywhere in that band — for a 0.55 kW motor at 230 V or a 1.1 kW motor at 400 V, for example. The magnetic trip is fixed at 78 A, so short-circuit protection clears fast on a hard fault without nuisance tripping on motor inrush. Breaking capacity is 100 kA Icu at 400/415 V AC (per IEC 60947-2), which means this breaker can safely interrupt a fault current up to 100,000 A without welding its contacts or rupturing. This is a motor-protection device for a control panel. It mounts horizontally or vertically on 35 mm DIN rail (snap-on) or screws to a backplate with the optional adaptor. The spring-cage power terminals accept 1...6 mm² solid or 1.5...4 mm² flexible with ferrules — two wires per terminal allowed. The 45 mm width is one standard modular unit, so it fits a typical 3-phase motor branch without crowding adjacent devices. Rated insulation voltage (Ui) is 690 V AC, impulse withstand voltage (Uimp) is 6 kV. Fire-resistance glow-wire test passes at 960 °C per IEC 60695-2-11. Climatic withstand conforms to IACS.","metaTitle":"Schneider TeSys GV2RT083 Motor Circuit Breaker, 4 A, Thermal","metaDescription":"GV2RT083 motor circuit breaker from Schneider Electric TeSys Deca range. Rated 4 A, thermal-magnetic trip, 100 kA breaking capacity at 400 V AC. Current lifecycle stage, sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.55 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.75 kW at 220/230 V AC 50/60 Hz motor protection high peak current 1.1 kW at 400/415 V AC 50/60 Hz motor protection high peak current 1.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current 1.5 kW at 440 V AC 50/60 Hz motor protection high peak current 1.5 kW at 500 V AC 50/60 Hz motor protection high peak current 2.2 kW at 500 V AC 50/60 Hz motor protection high peak current 2.2 kW at 690 V AC 50/60 Hz motor protection high peak current 3 kW at 690 V AC 50/60 Hz motor protection high peak current 1 kW at 230/240 V AC 50/60 Hz transformer protection 1.6 kW at 400/415 V AC 50/60 Hz transformer protection 2 kW at 400/415 V AC 50/60 Hz transformer protection 1.6 kW at 440 V AC 50/60 Hz transformer protection 2 kW at 440 V AC 50/60 Hz transformer protection 2 kW at 500 V AC 50/60 Hz transformer protection 2.5 kW at 500 V AC 50/60 Hz transformer protection 2.5 kW at 690 V AC 50/60 Hz transformer protection","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection Transformer","Operating altitude":"<= 2000 m","[In] rated current":"4 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: spring terminals 2 cable(s) 1...6 mm²solid Power circuit: spring terminals 2 cable(s) 1.5...4 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"78 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"2.5...4 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"4 A conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1a1201b16ffb02e4a6309e94ed2712a1.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2RT083/motor-circuit-breakertesys-deca3p2-54athermal-magneticspring-terminalstoggle-handle/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT083/alternatives.json"},"ai":{"faq":[{"question":"What is the thermal adjustment range of GV2RT083?","answer":"The thermal overload adjustment range is 2.5 to 4 A, set by a dial on the front of the breaker. This matches the motor full-load current within that band."},{"question":"What breaking capacity does GV2RT083 have at 400 V?","answer":"100 kA Icu at 400/415 V AC per IEC 60947-2. At 690 V AC the breaking capacity is 3 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT083","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT083 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}