{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2RT10AE11TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2RT10AE11TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2RT10AE11TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2RT10AE11TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2RT10AE11TQ, motor circuit breaker, 3P, 6.3 A rated current, thermal-magnetic, 100 kA breaking capacity, 1 NO + 1 NC aux contacts.","salesMarkdown":"It is designed for motor and transformer protection in AC networks, with a breaking capacity of 100 kA Icu at 400/415 V AC 50/60 Hz per IEC 60947-2. The 138 A magnetic trip setting handles inrush without nuisance trips, while the thermal element protects against sustained overloads. Suitability for isolation per IEC 60947-1 means it can serve as a disconnecting means in the motor branch circuit. The 6.3 A rated current (In) sets the continuous ampacity through the breaker. For motor protection, the unit covers 1.1 kW at 220/230 V and 2.2 kW at 400/415 V AC 50/60 Hz — match this to your motor nameplate FLA. The utilisation category AC-3 per IEC 60947-4-1 confirms it is rated for switching squirrel-cage motors during starting and running. Electrical durability is 100,000 cycles at AC-3, 415 V In — enough for frequent start-stop applications like conveyors or pumps. The 45 mm width (3-module) fits standard enclosure cutouts. IP20 finger-safe terminals accept up to 2 x 6 mm² solid or 2 x 4 mm² flexible with ferrule. Tightening torque is 1.7 N·m on the screw clamp terminals.","metaTitle":"Schneider TeSys GV2RT10AE11TQ Motor Circuit Breaker, 6.3 A,","metaDescription":"Schneider Electric TeSys GV2RT10AE11TQ motor circuit breaker, 6.3 A rated current, 100 kA breaking capacity at 400 V, thermal-magnetic trip, 1 NO + 1 NC aux contacts. Active produc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"1.1 kW at 220/230 V AC 50/60 Hz motor protection high peak current 2.2 kW at 400/415 V AC 50/60 Hz motor protection high peak current 2.2 kW at 440 V AC 50/60 Hz motor protection high peak current 3 kW at 440 V AC 50/60 Hz motor protection high peak current 3 kW at 500 V AC 50/60 Hz motor protection high peak current 4 kW at 690 V AC 50/60 Hz motor protection high peak current 1.6 kW at 230/240 V AC 50/60 Hz transformer protection 2 kW at 230/240 V AC 50/60 Hz transformer protection 2.5 kW at 400/415 V AC 50/60 Hz transformer protection 2.5 kW at 440 V AC 50/60 Hz transformer protection 4 kW at 440 V AC 50/60 Hz transformer protection 4 kW at 500 V AC 50/60 Hz transformer protection 4 kW at 690 V AC 50/60 Hz transformer protection","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2RT","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection Transformer","Operating altitude":"<= 2000 m","[In] rated current":"6.3 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"138 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC front","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"4...6.3 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"6.3 A conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5b6782497657de0fd13e30eaa2e14eb9.pdf","sourceUrl":"https://www.se.com/be/en/product/GV2RT10AE11TQ/motor-circuit-breakertesys-deca3p46-3athermal-magneticscrew-clamp-terminalswith-gvae11bulk-qty/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2RT10AE11TQ/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this motor circuit breaker?","answer":"Rated current 6.3 A, breaking capacity 100 kA Icu at 400/415 V AC, thermal-magnetic trip with 138 A magnetic setting, 1.1 kW motor at 230 V and 2.2 kW at 400 V, AC-3 utilisation category."},{"question":"What standards does the GV2RT10AE11TQ comply with?","answer":"It complies with EN/IEC 60947-2 (circuit-breakers) and EN/IEC 60947-4-1 (contactors and motor-starters), and is suitable for isolation per IEC 60947-1."},{"question":"Does it include auxiliary contacts?","answer":"Yes, it comes with 1 NO + 1 NC front-mounted auxiliary contacts for status signalling."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2RT10AE11TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2RT10AE11TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}