{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV3-ME14","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV3-ME14","canonicalUrl":"https://aoctrl.com/schneider/GV3-ME14","factsUrl":"https://aoctrl.com/api/mcp/products/GV3-ME14","rawCanonicalId":null},"summary":{"shortDescription":"GV3-ME14 - MOTOR CIRCUIT BREAKER by TELEMECANIQUE","salesMarkdown":null,"metaTitle":"Schneider GV3-ME14 Motor Circuit Breaker","metaDescription":"Schneider GV3-ME14 motor circuit breaker for industrial motor control systems.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"TeSys","Shock":"22 gn 20 ms conforming to IEC 60068-2-27","poles":"3","has_mpn":"GV3-ME14","power_w":"3 kW at 400...415 V AC 50/60 Hz 4 kW at 400...415 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz 7.5 kW at 660...690 V AC 50/60 Hz 5.5 kW at 660...690 V AC 50/60 Hz","depth_mm":"113","width_mm":"61","Standards":"IEC 60947-2 IEC 60947-4-1 BS EN DIN EN 60947-2 DIN EN 60947-4-1 EN 60947-2 EN 60947-4-1 NF EN","height_mm":"120","ip_rating":"IP20 conforming to IEC 60529 (open mounted) IP55 conforming to IEC 60529 (in enclosure)","torque_nm":"5 N.m - on EverLink BTR screw connectors - cable 2.5...16 mm² 5 N.m - on EverLink BTR screw connectors - cable 2.5...3.5 mm²","Rated Duty":"Continuous conforming to IEC 60947-4-1","Product Name":"TeSys GV3","control_type":"Push-button","frequency_hz":"50/60 Hz conforming to IEC 60947-4-1 50/60 Hz conforming to UL 50/60 Hz conforming to CSA","network_type":"AC","package_type":"PCE","mounting_type":"Fixed","Trip Unit Type":"Thermal-magnetic","altitude_max_m":"<= 3000 m","resistance_ohm":"2.5 gn (f= 0...25 Hz) conforming to IEC 60068-2-6","lifecycle_stage":"current","application_type":"Motor","supply_voltage_v":"690","Device Short Name":"thermal magnetic circuit breaker","Voltage Withstand":"6 kV conforming to IEC 60947-2","Voltage Insulation":"690 V conforming to IEC 60947-2","breaking_cap_icu_ka":"100","switching_current_a":"14","temperature_storage":"-40...80 °C","Protective Treatment":"TC","Utilization Category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1","Warranty (In Months)":"18","Electrical Life Cycles":"30000 cycles for AC-3 at 440 V In/2","Mechanical Life Cycles":"30000 cycles","Product Certifications":"UL CSA LROS (Lloyds register of shipping)","Connections - Terminals":"Power circuit: screw clamp terminal 1 cable(s) 2.5...35 mm²solid Power circuit: screw clamp terminal 1 cable(s) 2.5 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 16 mm²flexible with cable end","Phase Failure Sensitivity":"Yes conforming to IEC 60947-4-1 § 7-2-1-5-2","main_product_or_component_type":"Circuit breaker","Maximum Number Of Switchings Max":"25 cyc/h","ambient_air_temperature_operation_c":"-20"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$995.98","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/367d38298ef512e50dcf83c0e9129c7c.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV3-ME14/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV3-ME14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV3-ME14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}