{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV3P65","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV3P65","canonicalUrl":"https://aoctrl.com/schneider/GV3P65","factsUrl":"https://aoctrl.com/api/mcp/products/GV3P65","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV3P65, 3-pole motor circuit breaker, 65 A rated current, thermal-magnetic, AC-3, 30 kW at 400/415 V.","salesMarkdown":"The Schneider GV3P65 is a 3-pole thermal-magnetic motor circuit breaker from the TeSys Deca range, rated for 65 A continuous and covering motor loads up to 30 kW at 400/415 V AC. Magnetic trip is set at 910 A. Phase failure sensitivity is built in. The housing is 55 mm wide, 136 mm deep, and 132 mm tall – a standard footprint for a 65 A motor-protective device. IP20 finger-safe terminals and IK09 impact rating mean it tolerates routine panel access without a separate enclosure for shock protection. Standards compliance covers IEC 60947-2 (circuit-breaker) and 60947-4-1 (motor-starter), plus UL 60947-4-1 and CSA C22.2 – sufficient for most global panel specs.","metaTitle":"Schneider GV3P65 TeSys Deca Motor Circuit Breaker, 65A","metaDescription":"Schneider GV3P65 TeSys Deca motor circuit breaker. 65 A rated current, thermal-magnetic trip, 30 kW at 400 V AC-3. Active production, sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"5.4 in (136 mm)","Range":"TeSys Deca","Width":"2.2 in (55 mm)","Height":"5.2 in (132 mm)","Category":"US10I1122366","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with 3 x M4 screws)","Control Type":"Rotary handle","Network type":"AC","Product name":"TeSys GV3","Motor power kW":"30 kW 400/415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 12 kA Icu 500 V AC 50/60 Hz IEC 60947-2 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV3P","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Tightening torque":"44.3 lbf.in (5 N.m) screw clamp terminal","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"65 A","Operating altitude":"9842.52 ft (3000 m)","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"50000 cycles AC-3 415 V In","Mechanical durability":"50000 cycles","Mechanical robustness":"Shocks 15 Gn for 11 ms contactor open Shocks 30 Gn for 11 ms contactor closed Vibrations 4 Gn, 5...300 Hz","Nbr. of units in pkg.":"1","IK degree of protection":"IK09 enclosure","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"910 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"8 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Thermal protection adjustment range":"48...65 A IEC 60947-2","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"65 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 50 % 500 V AC 50/60 Hz IEC 60947-2 50 % 690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$83.82","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dfd28d11d1efbc957ec9f4345ea776bd.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV3P65/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the GV3P65 at 400 V?","answer":"50 kA Icu at 400/415 V AC per IEC 60947-2."},{"question":"What compliance documentation does the GV3P65 carry?","answer":"It meets EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and relevant clauses of IEC/EN 60335 for fire resistance."},{"question":"What is the colour and depth of the GV3P65?","answer":"Dark grey housing; depth is 136 mm (5.4 in)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV3P65","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV3P65 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}