{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV3P731","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV3P731","canonicalUrl":"https://aoctrl.com/schneider/GV3P731","factsUrl":"https://aoctrl.com/api/mcp/products/GV3P731","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV3P731 Motor Circuit Breaker, 3-Pole, 73 A, Thermal-Magnetic, Rotary Handle, Dark Grey.","salesMarkdown":"## Quick fit check for the BOM The GV3P731: Breaking capacity goes to 65 kA Icu at 230 V AC, 50 kA at 400 V — enough for most industrial panel SCCR targets. Magnetic trip set at 1120 A, phase failure sensitive per IEC 60947-4-1. ## Lifecycle & compliance doc GV3P731 is flagged as current production. No phase-out warning on the rider. RoHS, REACH, UL, IEC documentation is bundled with the TeSys Deca series — the datasheet pack covers the full family. ## Panel mounting & wiring Dimensions: 132 mm high, 55 mm wide, 136 mm deep. Rotary handle operates the mechanism; IP20 finger-safe terminals. IK09 enclosure rating means it can take a knock in a machine panel. Rated for uninterrupted duty, 50/60 Hz. Power dissipation 8 W per pole.","metaTitle":"Schneider GV3P731 TeSys Deca Motor Circuit Breaker, 73A, 3P","metaDescription":"Schneider GV3P731 TeSys Deca motor circuit breaker, 3-pole, 73 A, thermal-magnetic, current production. Sourced to order; compliance with IEC/EN 60947-4-1 and UL 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"5.4 in (136 mm)","Range":"TeSys Deca","Width":"2.2 in (55 mm)","Height":"5.2 in (132 mm)","Category":"US10I1122366","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with 3 x M4 screws)","Control Type":"Rotary handle","Network type":"AC","Product name":"TeSys GV3","Motor power kW":"37 kW 400/415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"65 kA Icu 230/240 V AC 50/60 Hz 50 kA Icu 400/415 V AC 50/60 Hz 50 kA Icu 440 V AC 50/60 Hz 12 kA Icu 500 V AC 50/60 Hz 6 kA Icu 690 V AC 50/60 Hz","Device short name":"GV3P","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Tightening torque":"44.3 lbf.in (5 N.m) screw clamp terminal","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"73 A","Operating altitude":"9842.52 ft (3000 m)","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"20000 cycles AC-3 415 V In","Mechanical durability":"50000 cycles","Mechanical robustness":"Shocks 5 Gn for 11 ms contactor open Shocks 30 Gn for 11 ms contactor closed Vibrations 4 Gn, 5...300 Hz","Nbr. of units in pkg.":"1","IK degree of protection":"IK09 enclosure","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"1120 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"8 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Thermal protection adjustment range":"62...73 A IEC 60947-2","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"73 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz 60 % 400/415 V AC 50/60 Hz 60 % 440 V AC 50/60 Hz 50 % 500 V AC 50/60 Hz 50 % 690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$468.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/44214bca27c5d4e29a5c79e4998f0614.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV3P731/alternatives.json"},"ai":{"faq":[{"question":"What is GV3P731's listed color?","answer":"The housing is dark grey, as per the spec."},{"question":"What is GV3P731's depth?","answer":"136 mm (5.4 inches) from the DIN rail mounting face to the front of the rotary handle."},{"question":"What compliance documentation does Schneider provide for GV3P731?","answer":"The part carries approvals for IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC 60335 household appliance clauses. RoHS and REACH declarations are available from the TeSys Deca documentation pack."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV3P731","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV3P731 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}