{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4AE11","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4AE11","canonicalUrl":"https://aoctrl.com/schneider/GV4AE11","factsUrl":"https://aoctrl.com/api/mcp/products/GV4AE11","rawCanonicalId":null},"summary":{"shortDescription":"TESYS BV4/GV4 AUX/ALARM CONTACT|TESYS BV4/GV4 AUX/ALARM CONTACT","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Range":"TeSys","Category":"US10I1122366","Mounting Mode":"Internal mounting","lifecycle_stage":"current","Quantity per Set":"Set of 1","Rated power in W":"DC-12 120 W 24 V IEC 60947-5-1 DC-12 120 W 48 V IEC 60947-5-1 DC-12 66 W 110 V IEC 60947-5-1 DC-12 75 W 250 V IEC 60947-5-1","Device short name":"GV4AE","Rated power in VA":"120 VA AC-12 24 V IEC 60947-5-1 240 VA AC-12 48 V IEC 60947-5-1 635 VA AC-12 110/127 V IEC 60947-5-1 1200 VA AC-12 230/240 V IEC 60947-5-1 2200 VA AC-12 380/440 V IEC 60947-5-1 3450 VA AC-12 660/690 V IEC 60947-5-1","Device Application":"Signalling","Mechanical durability":"40000 cycles","Nbr. of units in pkg.":"1","Wire stripping length":"0.3 in (8 mm)","Associated fuse rating":"5 A gG at 690 V conforming to IEC 60947-5-1","Connections - terminals":"Spring terminals 1 0.0008...0.002 in² (0.5...1.5 mm²) - cable stiffness: flexible without cable end","Minimum switching current":"2 mA","Minimum switching voltage":"17 V","Product or Component Type":"Auxiliary contact","Auxiliary contact composition":"1 NO/NC","[Ui] rated insulation voltage":"690 V IEC 60947-1","[Ie] rated operational current":"5 A 5 A 4 A 110/127 V AC-15 IEC 60947-5-1 3 A 220/240 V AC-15 IEC 60947-5-1 2.5 A 380...440 V AC-15 IEC 60947-5-1 0.11 A 660/690 V AC-15 IEC 60947-5-1 5 A 2.5 A 48 V DC-12 IEC 60947-5-1 0.6 A 110/127 V DC-12 IEC 60947-5-1 0.3 A 250 V DC-12 IEC 60947-5-1 2.5 A 1.2 A 48 V DC-12 IEC 60947-5-1 0.35 A 110/127 V DC-12 IEC 60947-5-1 0.05 A 250 V DC-12 IEC 60947-5-1 1 A 0.2 A 48 V DC-12 IEC 60947-5-1 0.05 A 110/127 V DC-12 IEC 60947-5-1 0.03 A 250 V DC-12 IEC 60947-5-1","[Ue] rated operational voltage":"<= 690 V","[Ith] conventional free air thermal current":"5 A IEC 60947-5-1 5 A CSA C22.2 No 14 5 A UL 508"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a725af687d3228632c595054d35e652.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4AE11/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4AE11","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4AE11 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}