{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4L03N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4L03N","canonicalUrl":"https://aoctrl.com/schneider/GV4L03N","factsUrl":"https://aoctrl.com/api/mcp/products/GV4L03N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV4L03N, 3-pole motor circuit breaker, 3.5 A rated current, magnetic-electronic trip, 100 kA breaking capacity at 240 V AC.","salesMarkdown":"The Schneider Electric GV4L03N is a 3-pole motor circuit breaker from the TeSys Deca range, rated at 3.5 A continuous current and designed for motor protection per IEC 60947-4-1. The 3.5 A rating means this breaker is sized for small motor loads — think fractional-horsepower pumps, fans, or conveyors on 400 V three-phase systems where the motor full-load current sits at or below that figure. The magnetic trip range of 21...49 A handles the inrush without nuisance tripping. ## Breaking capacity and fault handling Breaking capacity hits 100 kA Icu at 240 V AC and 50 kA at 415 V AC per IEC 60947-2. The breaker's role is protection and isolation, rated for 40,000 electrical cycles under AC-3 conditions at 440 V. The EverLink BTR connectors on top accept 1.5...70 mm² solid or 1.5...50 mm² flexible cable; the bottom terminals go up to 95 mm² solid. Tightening torque is 9 N·m for the larger cable range, 5 N·m for the smaller — a torque wrench is worth using here to avoid terminal heating under continuous load. IP40 front face with IK07 impact resistance suits it for enclosed panel mounting where occasional tool drops or panel-door knocks are expected. Compliance documentation covers EN/IEC 60947-2 and 60947-4-1, with a fire-resistance rating of 960 °C per IEC 60695-2-11 and climatic withstand per IACS for marine environments. The grey RAL 7016 housing is standard for the Deca range.","metaTitle":"GV4L03N TeSys Deca Motor Circuit Breaker, 3.5 A, 3P","metaDescription":"Schneider TeSys GV4L03N motor circuit breaker, 3.5 A rated current, 3-pole, 100 kA breaking capacity at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"165 mm","Range":"TeSys Deca","Width":"81 mm","title":"GV4L03N","Colour":"Grey (RAL 7016)","Height":"155 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1","Rated duty":"Continuous conforming to IEC 60947-4-1","description":"Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, magnetic, EverLink terminals","Control type":"Rotary handle","Product name":"TeSys GV4","Motor power kW":"0.55 kW at 400...415 V AC 50/60 Hz 0.75 kW at 400...415 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 1.1 kW at 660...690 V AC 50/60 Hz 1.5 kW at 660...690 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 660...690 V AC 50/60 Hz 1.1 kW at 400...415 V AC 50/60 Hz 1.5 kW at 400...415 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Pollution degree":"3","Range of product":"TeSys GV4","Breaking capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV4L","Poles description":"3P","Tightening torque":"9 N.m for cable 16...95 mm² 5 N.m for cable 1.5...10 mm²","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"5000 m","Operating position":"Any position","[In] rated current":"3.5 A","Trip unit technology":"Magnetic Electronic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1","Electrical durability":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"EverLink BTR screw connectors (top) 1 cable(s) 1.5...70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5...50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...70 mm² - flexible","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Magnetic tripping current":"21...49 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"6.1 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"115 A conforming to IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcfa7176fde233a64ef24549e9ce7afc.pdf","sourceUrl":"https://www.se.com/ie/en/product/GV4L03N/motor-circuit-breaker-tesys-gv4-3p-3-5a-icu-50ka-magnetic-everlink-terminals/"},"ai":{"faq":[{"question":"What is the breaking capacity of the GV4L03N at 415 V?","answer":"50 kA Icu at 380...415 V AC per IEC 60947-2. At 240 V it reaches 100 kA; at 690 V it drops to 8 kA."},{"question":"What cable sizes fit the GV4L03N terminals?","answer":"Top terminals accept 1.5...70 mm² solid or 1.5...50 mm² flexible; bottom terminals accept 2.5...95 mm² solid or 2.5...70 mm² flexible. Tightening torque is 9 N·m for the larger range, 5 N·m for the smaller."},{"question":"What compliance standards does the GV4L03N meet?","answer":"It is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, with a fire-resistance rating of 960 °C per IEC 60695-2-11 and climatic withstand per IACS for marine applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4L03N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4L03N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}