{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4L12N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4L12N6","canonicalUrl":"https://aoctrl.com/schneider/GV4L12N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4L12N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 series, GV4L12N6, 3-pole motor circuit breaker, 12.5 A rated current, magnetic-electronic trip, rotary handle control, IP40.","salesMarkdown":"The Schneider Electric GV4L12N6 is a 3-pole motor circuit breaker from the TeSys GV4 series, rated at 12.5 A continuous current. It combines magnetic and electronic trip technology to protect motor circuits against overloads and short circuits, with a magnetic tripping range of 75...175 A. Depth is 165 mm, which includes the rotary handle projection — account for that when spacing the enclosure door. Connection pitch is 27 mm without spreaders, 35 mm with them, so plan terminal-block alignment accordingly. Tightening torque is 9 N·m for cable cross-sections 16...95 mm² on the main power terminals, and 5 N·m for 1.5...10 mm² on the control/auxiliary terminals. Use ring-type lugs per the manufacturer's connection diagram. The enclosure itself carries IK07 impact resistance, sufficient for accidental tool contact during maintenance. Compliance documentation covers EN/IEC 60947-4-1 and EN/IEC 60947-2, which are the relevant standards for motor circuit breakers and low-voltage switchgear. For BOM freeze or PCN-watch purposes, this part has no announced change. If you need a second-source gate, the TeSys GV4 family includes other current ratings with the same physical footprint — but the 12.5 A magnetic-electronic trip curve is specific to this order code. ## Motor power sizing At 400...415 V AC, the GV4L12N6 covers motor power ratings from 3 kW up to 5.5 kW depending on the exact voltage and configuration. At 500 V, it covers 3 kW to 7.5 kW; at 660...690 V, it covers 5.5 kW to 11 kW. The 12.5 A rated current is the fixed thermal setting, so match it to the motor full-load current, not the nameplate kW alone. Power dissipation per pole is 6.1 W at rated current, giving a total of 18.3 W for the three poles. This heat must be considered when calculating enclosure ventilation, especially in a dense panel with multiple breakers.","metaTitle":"Schneider Electric GV4L12N6 TeSys GV4 Motor Circuit Breaker,","metaDescription":"Schneider Electric GV4L12N6 TeSys GV4 motor circuit breaker, 12.5 A rated current, 3-pole, magnetic-electronic trip, 100 kA breaking capacity at 240 V. Active production. Sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"165 mm","Width":"81 mm","Height":"155 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Rotary handle","Product Status":"Active","Terminal Pitch":"27 mm without spreaders 35 mm with spreaders","Trip Unit Type":"Magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Electrical Life Cycles":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5f910b3333fcc07aa49733d37efb1e21.pdf","sourceUrl":"https://www.se.com/nz/en/product/GV4L12N6/motor-circuit-breaker-tesys-gv4-3p-12-5a-icu-50ka-magnetic-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4L12N6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4L12N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4L12N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}