{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE02S","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE02S","canonicalUrl":"https://aoctrl.com/schneider/GV4LE02S","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE02S","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV4LE02S, motor circuit breaker, 3-pole, 2 A rated current, 120 kA breaking capacity at 240 V AC.","salesMarkdown":"It protects motor branch circuits against short-circuit and overload, with a magnetic trip unit that operates between 12 and 28 A. The breaking capacity reaches 120 kA Icu at 220...240 V AC, dropping to 10 kA at 660...690 V AC — enough to clear a high-fault utility feed without upstream fuses. It carries motor power ratings from 0.25 kW up to 1.5 kW depending on line voltage (400...690 V, 50/60 Hz). The toggle control and EverLink BTR screw terminals accept cables up to 95 mm² on the bottom and 70 mm² on top. Tightening torque is 9 N·m for the larger cables, 5 N·m for smaller ones. The unit fits any operating position and is rated for altitudes up to 5000 m. The GV4LE02S mounts directly to a DIN rail or panel plate. Its 81 mm width and 155 mm height fit standard TeSys Deca backplate cutouts. The IP40 front face and IK07 impact resistance are fine for enclosed industrial panels — not for washdown zones. Power dissipation per pole is 6.1 W at rated current, so three poles total about 18.3 W. The unit is rated for continuous duty per IEC 60947-4-1. Compliance documentation includes IEC 60947-2 and IEC 60947-4-1 certification. The part carries a suitability-for-isolation marking per IEC 60947-1. Climatic withstand conforms to IACS, and fire resistance is tested to 960 °C per IEC 60695-2-11. Storage temperature range is -50 to 85 °C, operating -25 to 70 °C. The magnetic trip range of 12...28 A means the instantaneous short-circuit trip is adjustable within that band — set it to match the motor's locked-rotor current. For a 0.25 kW motor at 400 V, that is typically around 4-5 A locked-rotor, so the lower end of the trip range provides adequate protection. Electrical durability is 40,000 cycles at AC-3 duty (motor switching) at 440 V, both at rated current and at half-rated current. Mechanical durability matches at 40,000 cycles. Maximum operating rate is 25 cycles per hour — fine for a pump or fan start, not for a high-speed indexing application. Vibration resistance per IEC 60068-2-6: ±1 mm at 2...13.2 Hz, 0.7 gn at 13.2...100 Hz. Shock resistance: 15 gn for 11 ms. This is typical for industrial cabinet mounting on a machine frame or near a conveyor drive.","metaTitle":"Schneider GV4LE02S TeSys Deca Motor Circuit Breaker, 2 A","metaDescription":"Schneider GV4LE02S TeSys Deca motor circuit breaker, rated 2 A, 120 kA breaking capacity at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"116 mm","Range":"TeSys Deca","Width":"81 mm","title":"GV4LE02S","Colour":"Grey (RAL 7016)","Height":"155 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous conforming to IEC 60947-4-1","description":"Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 100kA, magnetic, EverLink terminals","Control type":"Toggle","Product name":"TeSys GV4","Motor power kW":"0.25 kW at 400...415 V AC 50/60 Hz 0.37 kW at 400...415 V AC 50/60 Hz 0.55 kW at 400...415 V AC 50/60 Hz 0.75 kW at 400...415 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 0.55 kW at 660...690 V AC 50/60 Hz 0.75 kW at 660...690 V AC 50/60 Hz 1.1 kW at 660...690 V AC 50/60 Hz 1.5 kW at 660...690 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Pollution degree":"3","Range of product":"TeSys GV4","Breaking capacity":"120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV4L","Poles description":"3P","Tightening torque":"9 N.m for cable 16...95 mm² 5 N.m for cable 1.5...10 mm²","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"5000 m","Operating position":"Any position","[In] rated current":"2 A","Trip unit technology":"Magnetic Electronic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1","Electrical durability":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"EverLink BTR screw connectors (top) 1 cable(s) 1.5...70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5...50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...70 mm² - flexible","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Magnetic tripping current":"12...28 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"6.1 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"115 A conforming to IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$451.17","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4969f0b0f4d39ba065a18b2205d27807.pdf","sourceUrl":"https://www.se.com/ph/en/product/GV4LE02S/motor-circuit-breaker-tesys-gv4-3p-2a-icu-100ka-magnetic-everlink-terminals/"},"ai":{"faq":[{"question":"What are the key ratings for the GV4LE02S?","answer":"Rated current 2 A, magnetic trip adjustable 12...28 A, breaking capacity up to 120 kA at 240 V AC, rated operational voltage 690 V AC, motor power range 0.25 to 1.5 kW depending on line voltage."},{"question":"What standards does the GV4LE02S comply with?","answer":"It is certified to EN/IEC 60947-4-1 (motor protection) and EN/IEC 60947-2 (circuit-breaker). It also carries suitability-for-isolation marking per IEC 60947-1."},{"question":"What is the physical size of the GV4LE02S?","answer":"Width 81 mm, height 155 mm, depth 116 mm. It mounts on DIN rail or panel plate and fits standard TeSys Deca cutouts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE02S","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE02S when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}