{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE03N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE03N6","canonicalUrl":"https://aoctrl.com/schneider/GV4LE03N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE03N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV4L motor circuit breaker, 3-pole, 3.5 A rated current, magnetic-electronic trip, 100 kA breaking capacity at 240 V AC, IP40.","salesMarkdown":"It combines magnetic and electronic trip technology, with a rated current [In] of 3.5 A and a magnetic tripping range of 21 to 49 A. The breaking capacity hits 100 kA Icu at 240 V AC, dropping to 50 kA at 415 V and 8 kA at 690 V. That means this breaker clears faults up to 100 kA without upstream fuses or cascading failures — critical for high-fault installations like transformer-fed MCCs. This is a motor circuit breaker, not a plain branch-circuit breaker: the trip curve is shaped for motor inrush and overload profiles. The utilisation category is AC-3 per IEC 60947-4-1, meaning it's rated for switching squirrel-cage motors — starting, stopping, and running isolation. It also meets Category A per IEC 60947-2 for short-circuit performance. Connection pitch is 27 mm without spreaders, 35 mm with. Terminals accept lugs or ring terminals; tightening torque is 9 N·m for cable 16 to 95 mm², 5 N·m for 1.5 to 10 mm². IP40 front-of-panel protection; IK07 impact resistance. Operating altitude up to 5000 m, any mounting position. Rated current 3.5 A [In] sets the continuous thermal rating — the breaker will carry 3.5 A indefinitely at 40 °C ambient without tripping. The motor power table shows it protects motors from 0.55 kW up to 2.2 kW depending on voltage: 0.55 kW at 400 V, 1.1 kW at 690 V. That's a wider band than a fixed-thermal breaker because the electronic trip adjusts to the motor FLA setting. Power dissipation per pole is 6.1 W — three poles total 18.3 W at full load, which matters for enclosure thermal rise calculations. Electrical durability is rated at 40,000 cycles under AC-3 at 440 V — both at full load current and at half load. This is a moderate-duty industrial breaker, not a high-cycle machine-tool contactor; it's designed for motor start/stop service in conveyors, pumps, and fans, not for rapid jogging or high-frequency switching. It carries a fire-resistance rating of 960 °C per IEC 60695-2-11. Climatic withstand conforms to IACS (marine and offshore environmental testing). Storage temperature range is -50 to 85 °C; operating ambient is not explicitly listed but the continuous-duty rating implies standard 40 °C enclosure conditions.","metaTitle":"Schneider TeSys GV4LE03N6 Motor Circuit Breaker, 3.5 A, 100","metaDescription":"Schneider Electric TeSys GV4LE03N6 motor circuit breaker, 3.5 A rated current, 100 kA breaking capacity at 240 V. Active production. IEC 60947-2/4-1. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"116 mm","Width":"81 mm","Height":"155 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"27 mm without spreaders 35 mm with spreaders","Trip Unit Type":"Magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Electrical Life Cycles":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9611c314328365645e9b43d47e6d61e4.pdf","sourceUrl":"https://www.se.com/za/en/product/GV4LE03N6/motor-circuit-breaker-tesys-gv4-3p-3-5a-icu-50ka-magnetic-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4LE03N6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE03N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE03N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}