{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE03S","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE03S","canonicalUrl":"https://aoctrl.com/schneider/GV4LE03S","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE03S","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV4L motor circuit breaker, 3-pole, 3.5 A rated current, magnetic-electronic trip, breaking capacity up to 120 kA at 240 V AC.","salesMarkdown":"The Schneider Electric GV4LE03S is a TeSys Deca GV4L motor circuit breaker — a 3-pole device rated at 3.5 A continuous, designed for motor protection under IEC 60947-4-1 and IEC 60947-2. Its magnetic-electronic trip unit provides short-circuit and overload protection in a single enclosure, with a magnetic tripping window of 21...49 A that clears faults before they damage downstream contactors or the motor itself. Breaking capacity reaches 120 kA Icu at 220...240 V AC, 100 kA at 380...415 V, and 30 kA at 500 V — figures that cover most industrial distribution panels without needing a current-limiting upstream breaker. At 660...690 V it still interrupts 10 kA, so it holds up on 690 V line-fed motors. That's enough cross-section for the 3.5 A motor feed plus any tap-offs. IP40 enclosure with IK07 impact resistance suits clean indoor panels; the grey RAL 7016 housing resists marking. Operating altitude goes to 5000 m, and the ambient temperature range is -25...70 °C, so it handles unventilated enclosures near ovens or drives without derating. ## Key ratings in context Motor power coverage spans 0.55 kW to 2.2 kW depending on line voltage — 0.55 kW at 400...415 V, 0.75 kW at 500 V, 1.1 kW at 660...690 V, and 2.2 kW at 690 V. The 3.5 A rated current (In) is the continuous thermal setting; the magnetic trip (21...49 A) handles the start-up inrush without nuisance tripping. Electrical durability is rated at 40,000 cycles under AC-3 at 440 V at full load current — that's the motor-switching duty cycle. Mechanical endurance matches at 40,000 cycles. Maximum operating rate is 25 cycles per hour, so it's not intended for high-speed jogging or frequent reversing. Power dissipation per pole is 6.1 W, totalling about 18.3 W across all three poles at rated current. That's modest for a 3.5 A breaker, but if you're packing multiple units in a sealed enclosure, account for the heat rise.","metaTitle":"Schneider Electric GV4LE03S TeSys Deca Motor Circuit Breaker","metaDescription":"Schneider Electric GV4LE03S TeSys Deca motor circuit breaker, 3.5 A rated current, 3-pole, breaking capacity up to 120 kA at 240 V. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"116 mm","Range":"TeSys Deca","Width":"81 mm","title":"GV4LE03S","Colour":"Grey (RAL 7016)","Height":"155 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous conforming to IEC 60947-4-1","description":"Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, magnetic, EverLink terminals","Control type":"Toggle","Product name":"TeSys GV4","Motor power kW":"0.55 kW at 400...415 V AC 50/60 Hz 0.75 kW at 400...415 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 1.1 kW at 660...690 V AC 50/60 Hz 1.5 kW at 660...690 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 660...690 V AC 50/60 Hz 1.1 kW at 400...415 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Pollution degree":"3","Range of product":"TeSys GV4","Breaking capacity":"120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV4L","Poles description":"3P","Tightening torque":"9 N.m for cable 16...95 mm² 5 N.m for cable 1.5...10 mm²","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"5000 m","Operating position":"Any position","[In] rated current":"3.5 A","Trip unit technology":"Magnetic Electronic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1","Electrical durability":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"EverLink BTR screw connectors (top) 1 cable(s) 1.5...70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5...50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...70 mm² - flexible","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Magnetic tripping current":"21...49 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"6.1 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"115 A conforming to IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$426.73","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aaf3a1c7e248d9e37a6a794ff22c70c0.pdf","sourceUrl":"https://www.se.com/ph/en/product/GV4LE03S/motor-circuit-breaker-tesys-gv4-3p-3-5a-icu-100ka-magnetic-everlink-terminals/"},"ai":{"faq":[{"question":"What is the breaking capacity of the GV4LE03S?","answer":"Breaking capacity is 120 kA Icu at 220...240 V AC, 100 kA at 380...415 V, 70 kA at 440 V, 30 kA at 500 V, 18 kA at 525 V, and 10 kA at 660...690 V, all per IEC 60947-2."},{"question":"What motor power does the GV4LE03S protect?","answer":"It covers 0.55 kW to 2.2 kW depending on line voltage: 0.55 kW at 400...415 V, 0.75 kW at 500 V, 1.1 kW at 660...690 V, and 2.2 kW at 690 V."},{"question":"What compliance documentation is available for the GV4LE03S?","answer":"The device is certified to EN/IEC 60947-4-1 and EN/IEC 60947-2. It carries a suitability-for-isolation mark per IEC 60947-1 and a fire-resistance rating of 960 °C per IEC 60695-2-11. Climatic withstand conforms to IACS."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE03S","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE03S when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}