{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE07S","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE07S","canonicalUrl":"https://aoctrl.com/schneider/GV4LE07S","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE07S","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV4L, GV4LE07S, 3-pole motor circuit breaker, 7 A In, 120 kA Icu at 240 V AC, 100 kA at 415 V AC.","salesMarkdown":"## What It Is and the Rating That Decides Fit The Schneider Electric GV4LE07S is a 3-pole motor circuit breaker from the TeSys Deca range, rated 7 A continuous current (In) and built for motor protection duty under EN/IEC 60947-4-1 and EN/IEC 60947-2. The headline number is the 7 A In — that is the continuous current the thermal-magnetic trip allows before overload protection acts. For a 400 V three-phase supply, this breaker covers motor outputs from 1.5 kW up to 3 kW depending on the exact line voltage, and up to 7.5 kW at 690 V. The magnetic trip is set at 42...98 A, so it handles the inrush of a motor up to about 14x FLC without nuisance tripping. ## Breaking Capacity — What It Means for Coordination The short-circuit breaking capacity (Icu) is 120 kA at 240 V AC, 100 kA at 415 V, and still 10 kA at 690 V. The Utilisation Category A (IEC 60947-2) confirms it is not intended for selectivity under fault; if you need full discrimination, pair it with a TeSys GV7 or a fuse-switch upstream. Panel fit: 81 mm wide, 155 mm high, 116 mm deep. Screw terminals on top accept 1.5...70 mm² solid or 1.5...50 mm² flexible; bottom terminals accept up to 95 mm² solid. Tightening torque is 9 N·m for the larger cable range.","metaTitle":"Schneider GV4LE07S TeSys Deca Motor Circuit Breaker, 7 A, 12","metaDescription":"Schneider Electric GV4LE07S TeSys Deca motor circuit breaker, 3-pole, 7 A rated current, 120 kA breaking capacity at 240 V AC. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"116 mm","Width":"81 mm","Height":"155 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Trip Unit Type":"Magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Electrical Life Cycles":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$416.21","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/76940cedbe9fa3225b2f1a5f5aa023b6.pdf","sourceUrl":"https://www.se.com/za/en/product/GV4LE07S/motor-circuit-breaker-tesys-gv4-3p-7-a-icu-100-ka-magnetic-everlink-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4LE07S/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE07S","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE07S when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}