{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE07S6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE07S6","canonicalUrl":"https://aoctrl.com/schneider/GV4LE07S6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE07S6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4, motor circuit breaker, 3P, 7 A rated current, magnetic-electronic trip, 120 kA breaking capacity at 240 V AC.","salesMarkdown":"It combines magnetic and electronic trip technology to protect motor circuits against short-circuits and overloads, with a magnetic tripping window of 42...98 A. Rated for AC-3 duty per IEC 60947-4-1, it handles the high inrush of squirrel-cage motors during starting and the lower running current under load. The 7 A frame covers motor outputs from 1.5 kW up to 7.5 kW depending on supply voltage (400 V to 690 V AC). Breaking capacity reaches 120 kA Icu at 240 V AC and 100 kA at 415 V AC per IEC 60947-2, meaning it can safely interrupt a fault current up to that level without welding contacts or cascading damage upstream. This is a strong SCCR for a 7 A frame — suitable for high-fault installations. The GV4L footprint is 81 mm wide, 155 mm high, and 116 mm deep — a compact 3-pole block that mounts on a DIN rail or panel. Connection pitch is 27 mm without spreaders, widening to 35 mm with spreaders for larger cable lugs. Terminal tightening torque is 9 N·m for the main power cables (16...95 mm²) and 5 N·m for control wiring (1.5...10 mm²). IP40 front protection and IK07 impact resistance suit it for enclosed panel installation where occasional tool drops or debris are a risk. For motor protection, you size this to match the motor's full-load current, not the nameplate kW. The magnetic trip setting of 42...98 A is fixed and non-adjustable — it must fall above the motor's starting inrush to avoid nuisance trips. Electrical durability is 40,000 cycles at AC-3 duty at 440 V — a solid service life for a motor-starter application. Mechanical durability matches at 40,000 cycles. Maximum operating rate is 25 cycles per hour, so it is not intended for high-speed jogging or rapid cycling. Power dissipation per pole is 6.1 W, totaling about 18.3 W for the three poles at full rated current. This matters for thermal management inside a sealed enclosure — check the cabinet's temperature rise if multiple breakers are ganged together.","metaTitle":"Schneider TeSys GV4LE07S6 Motor Circuit Breaker, 7 A, 3P","metaDescription":"Schneider GV4LE07S6 motor circuit breaker, 7 A rated current, 3 poles, TeSys Deca range. 120 kA breaking capacity at 240 V AC. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"116 mm","Range":"TeSys Deca","Width":"81 mm","title":"GV4LE07S6","Colour":"Grey (RAL 7016)","Height":"155 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous conforming to IEC 60947-4-1","description":"Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, magnetic, lugs terminals","Control type":"Toggle","Product name":"TeSys GV4","Motor power kW":"1.5 kW at 400...415 V AC 50/60 Hz 2.2 kW at 400...415 V AC 50/60 Hz 2.5 kW at 400...415 V AC 50/60 Hz 3 kW at 400...415 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz 2.5 kW at 500 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 660...690 V AC 50/60 Hz 7.5 kW at 660...690 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"27 mm without spreaders 35 mm with spreaders","Pollution degree":"3","Range of product":"TeSys GV4","Breaking capacity":"120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV4L","Poles description":"3P","Tightening torque":"9 N.m for cable 16...95 mm² 5 N.m for cable 1.5...10 mm²","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"5000 m","Operating position":"Any position","[In] rated current":"7 A","Trip unit technology":"Magnetic Electronic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1","Electrical durability":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Magnetic tripping current":"42...98 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"6.1 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"115 A conforming to IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/47b75a8c8c9d6541aa089da6d47420cf.pdf","sourceUrl":"https://www.se.com/ph/en/product/GV4LE07S6/motor-circuit-breaker-tesys-gv4-3p-7a-icu-100ka-magnetic-lugs-terminals/"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The three numbers that decide fit are: 7 A rated current (In), 42...98 A magnetic trip range, and the breaking capacity at your system voltage (e.g., 100 kA at 415 V AC). The motor power kW table covers 1.5 kW to 7.5 kW depending on supply voltage."},{"question":"What standards does this breaker comply with?","answer":"It is certified to EN/IEC 60947-4-1 (motor starters) and EN/IEC 60947-2 (circuit breakers). It is suitable for isolation per IEC 60947-1. Climatic withstand conforms to IACS."},{"question":"What is the physical size of the GV4LE07S6?","answer":"The dimensions are 81 mm wide, 155 mm high, and 116 mm deep. It is a 3-pole block for DIN-rail or panel mounting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE07S6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE07S6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}