{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE07S6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE07S6","canonicalUrl":"https://aoctrl.com/schneider/GV4LE07S6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE07S6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4, motor circuit breaker, 3P, 7 A rated current, magnetic-electronic trip, 120 kA breaking capacity at 240 V AC.","salesMarkdown":"It combines magnetic and electronic trip technology to protect motor circuits against short-circuits and overloads, with a magnetic tripping window of 42...98 A. Rated for AC-3 duty per IEC 60947-4-1, it handles the high inrush of squirrel-cage motors during starting and the lower running current under load. The 7 A frame covers motor outputs from 1.5 kW up to 7.5 kW depending on supply voltage (400 V to 690 V AC). Breaking capacity reaches 120 kA Icu at 240 V AC and 100 kA at 415 V AC per IEC 60947-2, meaning it can safely interrupt a fault current up to that level without welding contacts or cascading damage upstream. This is a strong SCCR for a 7 A frame — suitable for high-fault installations. The GV4L footprint is 81 mm wide, 155 mm high, and 116 mm deep — a compact 3-pole block that mounts on a DIN rail or panel. Connection pitch is 27 mm without spreaders, widening to 35 mm with spreaders for larger cable lugs. Terminal tightening torque is 9 N·m for the main power cables (16...95 mm²) and 5 N·m for control wiring (1.5...10 mm²). IP40 front protection and IK07 impact resistance suit it for enclosed panel installation where occasional tool drops or debris are a risk. For motor protection, you size this to match the motor's full-load current, not the nameplate kW. The magnetic trip setting of 42...98 A is fixed and non-adjustable — it must fall above the motor's starting inrush to avoid nuisance trips. Electrical durability is 40,000 cycles at AC-3 duty at 440 V — a solid service life for a motor-starter application. Mechanical durability matches at 40,000 cycles. Maximum operating rate is 25 cycles per hour, so it is not intended for high-speed jogging or rapid cycling. Power dissipation per pole is 6.1 W, totaling about 18.3 W for the three poles at full rated current. This matters for thermal management inside a sealed enclosure — check the cabinet's temperature rise if multiple breakers are ganged together.","metaTitle":"Schneider TeSys GV4LE07S6 Motor Circuit Breaker, 7 A, 3P","metaDescription":"Schneider GV4LE07S6 motor circuit breaker, 7 A rated current, 3 poles, TeSys Deca range. 120 kA breaking capacity at 240 V AC. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"116 mm","Width":"81 mm","Height":"155 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"27 mm without spreaders 35 mm with spreaders","Trip Unit Type":"Magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Electrical Life Cycles":"40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/47b75a8c8c9d6541aa089da6d47420cf.pdf","sourceUrl":"https://www.se.com/ph/en/product/GV4LE07S6/motor-circuit-breaker-tesys-gv4-3p-7a-icu-100ka-magnetic-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4LE07S6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE07S6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE07S6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}