{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE115N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE115N6","canonicalUrl":"https://aoctrl.com/schneider/GV4LE115N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE115N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, TeSys Deca series, GV4LE115N6 motor circuit breaker, 3P, 115 A In, 100 kA Icu at 240 V AC, 50/60 Hz.","salesMarkdown":"It's a 3-pole unit with a toggle control, designed for motor protection in industrial control panels. The headline breaking capacity is 100 kA Icu at 220...240 V AC, dropping to 50 kA at 380...415 V AC and 15 kA at 525 V AC. That's enough SCCR headroom for most industrial service-entrance or sub-distribution boards fed by a transformer of moderate impedance. The magnetic trip is set at 480...1120 A, meaning it clears bolted faults fast while riding through normal motor inrush. ## Motor power and application fit The GV4LE115N6 covers a wide motor power band depending on the supply voltage: 37 kW at 400 V, 55 kW at 500 V, and up to 110 kW at 690 V. The trip unit is magnetic-electronic, so it provides both short-circuit and overload protection in a single device. For a 115 A motor circuit breaker, this is the range you'd expect for a 37–55 kW motor at common European voltages. Utilisation category is AC-3 per IEC 60947-4-1, which is the standard for squirrel-cage motors — starting, stopping, and occasional plugging. The electrical durability is 10,000 cycles at AC-3 at 440 V with half-rated current, and 5,000 cycles at full-rated current. Mechanical durability is 40,000 cycles. That's a solid service life for a motor branch circuit in a conveyor, pump, or fan application. The breaker measures 155 mm high by 81 mm wide by 116 mm deep. The connection pitch is 27 mm without spreaders, expanding to 35 mm with spreaders — important to note when laying out the gland plate and busbar runs in a dense panel. IP40 protection means it's fine inside a clean enclosure but not for washdown areas. The IK07 impact rating handles accidental tool drops. Operating altitude goes to 5000 m, which covers most high-altitude installations without derating. Terminals accept lugs or ring terminals for cable from 1.5 to 95 mm², with tightening torques of 5 N.m for the smaller range and 9 N.m for the larger. That's a robust connection range — enough for the 115 A rating with standard copper cable.","metaTitle":"Schneider Electric GV4LE115N6 TeSys Deca Motor Circuit Break","metaDescription":"Schneider Electric GV4LE115N6 TeSys Deca motor circuit breaker, 115 A rated current, 100 kA breaking capacity at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"116 mm","Width":"81 mm","Height":"155 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"27 mm without spreaders 35 mm with spreaders","Trip Unit Type":"Magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Electrical Life Cycles":"10000 cycles for AC-3 at 440 V In/2 5000 cycles for AC-3 at 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/GV4LE115N6/motor-circuit-breaker-tesys-gv4-3p-115a-icu-50ka-magnetic-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4LE115N6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE115N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE115N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}