{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE50N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE50N6","canonicalUrl":"https://aoctrl.com/schneider/GV4LE50N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE50N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 series, GV4LE50N6 motor circuit breaker, 3-pole, 50 A rated current, 100 kA breaking capacity at 240 V AC, magnetic-electronic trip.","salesMarkdown":"The GV4LE50N6 is a 3-pole motor circuit breaker from Schneider's TeSys GV4 family, rated 50 A continuous and built to protect motor circuits up to 22 kW at 400 V or 45 kW at 690 V. The magnetic trip window is adjustable from 300 to 700 A, so you set the instantaneous pickup just above the motor's inrush without nuisance tripping on a hard start. ## Standards and approvals — what they certify That dual standard is the key: it acts as both a motor disconnect with overload protection and a branch-circuit short-circuit protective device. ## Integration notes — mounting and wiring Terminal lugs accept cable from 1.5 to 95 mm², with tightening torque of 5 N·m for the smaller wires and 9 N·m for the heavier ones. The connection pitch is 27 mm without spreaders, 35 mm with — that matters when you're laying out a multi-breaker lineup and need to match busbar spacing. Operating position is any orientation, which gives flexibility in tight enclosures. The mechanical durability is 40,000 cycles, electrical durability 20,000 at AC-3 duty at half load, so it's built for frequent switching in conveyor or pump applications.","metaTitle":"Schneider GV4LE50N6 TeSys GV4 Motor Circuit Breaker, 50 A, 1","metaDescription":"GV4LE50N6 motor circuit breaker, 50 A rated, 100 kA breaking at 240 V. Active production. EN/IEC 60947-4-1 & -2. Magnetic-electronic trip. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"116 mm","Width":"81 mm","Height":"155 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"27 mm without spreaders 35 mm with spreaders","Trip Unit Type":"Magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Electrical Life Cycles":"20000 cycles for AC-3 at 440 V In/2 10000 cycles for AC-3 at 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/GV4LE50N6/motor-circuit-breaker-tesys-gv4-3p-50a-icu-50ka-magnetic-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4LE50N6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE50N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE50N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}