{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4LE80S6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4LE80S6","canonicalUrl":"https://aoctrl.com/schneider/GV4LE80S6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4LE80S6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4LE80S6, 3-pole, 80 A rated current, 120 kA breaking capacity at 240 V AC, 37 kW at 400 V AC.","salesMarkdown":"It combines magnetic and electronic trip technology to protect against short circuits and overloads, with a breaking capacity of 120 kA Icu at 240 V AC and 100 kA at 415 V AC per IEC 60947-2. The 80 A rating sets the motor full-load current threshold — wire it for a 37 kW motor at 400 V or up to 55 kW at 690 V. Rated for AC-3 duty per IEC 60947-4-1, this breaker handles the inrush of squirrel-cage motors during starting and switching. The magnetic trip range is 480–1120 A, adjustable to coordinate with motor starting characteristics. Continuous duty rated per IEC 60947-4-1 means it carries the 80 A load indefinitely without derating in a 40 °C ambient. The GV4LE80S6 measures 155 mm high, 81 mm wide, and 116 mm deep — a compact 3-pole footprint for DIN-rail or screw-mount installation in a motor control center. Connection pitch is 27 mm without spreaders, 35 mm with them, accepting lugs or ring terminals up to 95 mm² cable at 9 N·m torque. IP40 front protection keeps out tools and fingers; IK07 impact rating handles panel-door knocks. Operates in any position at altitudes up to 5000 m, with storage from -50 to 85 °C. Fire resistance rated at 960 °C per IEC 60695-2-11. Approvals include EN/IEC 60947-2 and 60947-4-1, with suitability for isolation per IEC 60947-1. Climatic withstand conforms to IACS for marine and humid environments. No UL listing is stated in the evidence, so verify for North American panel builds.","metaTitle":"Schneider Electric GV4LE80S6 TeSys GV4 Motor Circuit Breaker","metaDescription":"Schneider Electric GV4LE80S6 TeSys GV4 motor circuit breaker, 80 A rated current, 120 kA breaking capacity at 240 V, 37 kW at 400 V. Current lifecycle stage, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"116 mm","Width":"81 mm","Height":"155 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"27 mm without spreaders 35 mm with spreaders","Trip Unit Type":"Magnetic Electronic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Electrical Life Cycles":"14000 cycles for AC-3 at 440 V In/2 7000 cycles for AC-3 at 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/eg/en/product/GV4LE80S6/motor-circuit-breaker-tesys-gv4-3p-80-a-icu-100-ka-magnetic-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4LE80S6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4LE80S6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4LE80S6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}