{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4P115B6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4P115B6","canonicalUrl":"https://aoctrl.com/schneider/GV4P115B6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4P115B6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 series, GV4P115B6, 3-pole motor circuit breaker, 115 A rated current, electronic thermal-magnetic trip, 50 kA Icu at 240 V AC.","salesMarkdown":"The Schneider Electric TeSys GV4 GV4P115B6 is a 3-pole motor circuit breaker rated at 115 A continuous, with electronic thermal-magnetic trip. It protects motors under IEC 60947-4-1 and UL 60947-4-1, with a magnetic trip fixed at 1955 A. It is phase failure sensitive and suitable for isolation. ## Mounting & Connections Dimensions: 6.1 x 3.2 x 6.5 in (155 x 81 x 165 mm). Accepts lug/ring terminals with a tightening torque of 79.7 lbf.in (9 N·m) for wire sizes up to 95 mm² (with spreaders at 35 mm pitch, or 27 mm without). Operating position is any orientation. IP40 front and IK07 impact protection. Pollution degree 3 rated. ## Protection Performance Trip technology is electronic thermal-magnetic with fixed magnetic trip at 1955 A. Electrical durability: 10,000 cycles at AC-3, In/2; 5,000 cycles at full In. Mechanical durability 40,000 cycles. Utilisation category A (IEC 60947-2) and AC-3 (IEC 60947-4-1). Suitable for isolation per IEC 60947-1. Phase failure sensitivity is standard. ## Standards & Environment Certified to CSA C22.2 No. 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. Fire resistance tested at 960 °C per IEC 60695-2-11. Climatic withstand IACS. Operating altitude up to 5000 m. Rated for continuous duty.","metaTitle":"Schneider TeSys GV4 GV4P115B6 Motor Circuit Breaker, 115 A","metaDescription":"Active 3-pole motor circuit breaker, 115 A continuous, electronic thermal-magnetic trip, 50 kA breaking at 240 V UL. AC-3, phase failure sensitive, isolation rated. Gray RAL 7016,","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"6.5 in (165 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Rotary handle","Product name":"TeSys GV4","Motor power kW":"37 kW 400...415 V AC 50/60 Hz 45 kW 400...415 V AC 50/60 Hz 55 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 500 V AC 50/60 Hz 75 kW 500 V AC 50/60 Hz 75 kW 660...690 V AC 50/60 Hz 90 kW 660...690 V AC 50/60 Hz 110 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4P","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"115 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Electronic Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"1955 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$825.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aab7391e2e669fad4488b1127bc29d53.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4P115B6/alternatives.json"},"ai":{"faq":[{"question":"What is the listed color of the GV4P115B6?","answer":"Gray RAL 7016."},{"question":"What is the depth of the GV4P115B6?","answer":"6.5 in (165 mm)."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The GV4P115B6 is certified to CSA, UL, and IEC standards for motor circuit breakers. It also meets fire resistance at 960 °C, IP40/IK07, and climatic withstand IACS."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4P115B6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4P115B6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}