{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4P25N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4P25N6","canonicalUrl":"https://aoctrl.com/schneider/GV4P25N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4P25N6","rawCanonicalId":null},"summary":{"shortDescription":"TeSys GV4 motor circuit breaker, GV4P25N6, 25 A, 3-pole, 100 kA interrupting at 240 V.","salesMarkdown":"## Part overview and fit The TeSys GV4 GV4P25N6 is a 3-pole motor circuit breaker rated for 25 A continuous line current, with an electronic thermal-magnetic trip unit for motor protection. It is sized for 7.5 kW motors at 400–415 V AC and up to 15 kW at 500 V AC. Breaking capacity reaches 100 kA at 240 V AC (IEC 60947-2) and 65 kA at 240 V UL; at 480 V UL it drops to 35 kA — enough for most 480Y/277 V distribution panels. AC-3 utilization category (IEC 60947-4-1) confirms it handles motor starting currents up to 25 A. Phase failure sensitivity is included, so it will trip on single-phasing. Mechanical durability is 40,000 cycles; electrical durability at 440 V AC-3 is 40,000 cycles at full load current and 20,000 at 2× In. Maximum operating rate: 25 cycles per hour. ## Mounting and connection The breaker occupies a 81 mm wide × 155 mm high footprint with a 27 mm connection pitch (35 mm with spreaders). Terminal acceptance: lugs or ring terminals up to 95 mm² for line and load. Tightening torque is 9 N·m for the larger terminals (16–95 mm²) and 5 N·m for the smaller (1.5–10 mm²). Rotary handle control, any operating position, and IP40 enclosure protection. IK07 impact resistance. Power dissipation per pole is 4.6 W at 25 A rated current. ## Compliance and certifications Rated to CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. Pollution degree 3, climatic withstand IACS. Fire resistance 960 °C per IEC 60695-2-11. Suitable for isolation per IEC 60947-1.","metaTitle":"GV4P25N6 TeSys GV4 Motor Circuit Breaker, 25 A, 3P","metaDescription":"GV4P25N6 TeSys GV4 3-pole motor circuit breaker, 25 A rated, 100 kA breaking at 240 V. UL, CSA, IEC 60947 rated. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"6.5 in (165 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Rotary handle","Product name":"TeSys GV4","Motor power kW":"7.5 kW 660...690 V AC 50/60 Hz 5.5 kW 400...415 V AC 50/60 Hz 7.5 kW 500 V AC 50/60 Hz 9 kW 660...690 V AC 50/60 Hz 11 kW 660...690 V AC 50/60 Hz 7.5 kW 400...415 V AC 50/60 Hz 9 kW 400...415 V AC 50/60 Hz 11 kW 400...415 V AC 50/60 Hz 9 kW 500 V AC 50/60 Hz 11 kW 500 V AC 50/60 Hz 15 kW 500 V AC 50/60 Hz 15 kW 660...690 V AC 50/60 Hz 18.5 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4P","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"25 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Electronic Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"40000 cycles AC-3 440 V In/2 20000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"425 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aab7391e2e669fad4488b1127bc29d53.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4P25N6/alternatives.json"},"ai":{"faq":[{"question":"What is the color of the GV4P25N6?","answer":"The GV4P25N6 is gray, RAL 7016."},{"question":"What is the depth of the GV4P25N6?","answer":"Depth is 6.5 inches (165 mm)."},{"question":"What compliance standards does the GV4P25N6 meet?","answer":"The breaker is UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN/IEC 60947-4-1 as well as EN/IEC 60947-2 listed. It also has fire resistance to 960 °C and pollution degree 3 rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4P25N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4P25N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}