{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PE02N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PE02N6","canonicalUrl":"https://aoctrl.com/schneider/GV4PE02N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PE02N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PE02N6, 2 A, 3-pole, thermal-magnetic electronic trip, IP40, Gray RAL 7016.","salesMarkdown":"## Motor circuit breaker for heavy industrial protection The Schneider Electric GV4PE02N6 is a 3-pole motor circuit breaker in the TeSys Deca range, rated 2 A continuous current for motor protection per EN/IEC 60947-4-1 and UL 60947-4-1, with CSA C22.2 No 60947-4-1 compliance. Trip technology is thermal-magnetic electronic, including phase failure sensitivity per IEC 60947-4-1 and magnetic tripping at 34 A. ## Breaking capacity and fault handling Breaking capacity reaches 100 kA Icu at 220–240 V AC under IEC 60947-2 and 65 kA at 240 V AC under UL 60947, providing high SCCR for industrial motor circuits. At 380–415 V AC, Icu is 50 kA; at 660–690 V AC, 8 kA. Mechanical and electrical durability rated at 40,000 cycles in AC-3 duty at 440 V, with a maximum operating rate of 25 cycles per hour. ## Mounting and environmental ratings IP40 enclosure with IK07 impact resistance, pollution degree 3, and operating altitude up to 5000 m. Line and load terminals accept 16–95 mm² lugs or ring terminals; tightening torque 79.7 lbf·in (9 N·m). Fire resistance tested to 1760 °F (960 °C) per IEC 60695-2-11.","metaTitle":"Schneider GV4PE02N6 TeSys GV4 Motor Circuit Breaker, 2 A","metaDescription":"Schneider Electric TeSys GV4 motor circuit breaker GV4PE02N6, 2 A rated current, 3-pole, thermal-magnetic protection, 100 kA breaking capacity at 240 V, UL/CSA/IEC listed. Gray RAL","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"0.25 kW 400...415 V AC 50/60 Hz 0.37 kW 400...415 V AC 50/60 Hz 0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 0.55 kW 660...690 V AC 50/60 Hz 0.75 kW 660...690 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PE","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"2 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Thermal-magnetic Electronic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"34 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fc98dd72ff5c86e232662c4f979abdf6.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PE02N6/alternatives.json"},"ai":{"faq":[{"question":"What is GV4PE02N6's listed color?","answer":"Gray RAL 7016."},{"question":"What is GV4PE02N6's listed depth?","answer":"4.6 in (116 mm)."},{"question":"What compliance documentation does this brand provide for GV4PE02N6?","answer":"It meets CSA C22.2 No 60947-4-1, UL 60947-4-1, and EN/IEC 60947-4-1 and EN/IEC 60947-2. Fire resistance is tested to 1760 °F (960 °C) per IEC 60695-2-11."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PE02N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PE02N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}