{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PE03N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PE03N","canonicalUrl":"https://aoctrl.com/schneider/GV4PE03N","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PE03N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PE03N, 3.5 A rated current, 3-pole, electronic thermal-magnetic trip, IP40, gray RAL 7016.","salesMarkdown":"## Motor circuit breaker for 3.5 A protection The GV4PE03N is a 3-pole motor circuit breaker from the TeSys Deca range, rated 3.5 A continuous. It sits between the supply and a motor up to 0.75 kW at 400 V AC (or 1.5 kW at 500 V). The electronic thermal-magnetic trip unit gives both overload and short-circuit protection; magnetic trip kicks in at 59 A. Phase failure sensitivity is built in per IEC 60947-4-1, so it catches a lost phase before the motor cooks. That covers most industrial panels with high fault current; you can use it in a line-up without worrying about series rating. For 480Y/277 V UL systems it still holds 35 kA. Climatic withstand meets IACS; operating altitude up to 5000 m. The EverLink BTR screw terminals accept solid copper up to 95 mm² bottom / 70 mm² top, or flexible up to 70 mm² bottom / 50 mm² top. Tightening torque is 9 N·m for the power terminals. IP40 front face keeps dust out; IK07 impact resistance. Toggle control with 25 cycles/hour max operating rate. 40000 mechanical cycles, same for electrical at AC-3. Fits any mounting position.","metaTitle":"Schneider GV4PE03N Motor Circuit Breaker, 3.5 A, TeSys Deca","metaDescription":"GV4PE03N motor circuit breaker, 3.5 A rated current, 100 kA breaking capacity at 240 V. Active production, TeSys Deca range, IP40. RFQ for BOM line.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz 1.5 kW 500 V AC 50/60 Hz 2.2 kW 660...690 V AC 50/60 Hz 1.1 kW 400...415 V AC 50/60 Hz 1.5 kW 400...415 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PE","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"3.5 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Electronic Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"EverLink BTR screw connectors top) 1 0.002...0.1 in² (1.5...70 mm²) - solid EverLink BTR screw connectors top) 1 0.002...0.08 in² (1.5...50 mm²) - flexible EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...95 mm²) - solid EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...70 mm²) - flexible","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"59 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$770.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fc98dd72ff5c86e232662c4f979abdf6.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PE03N/alternatives.json"},"ai":{"faq":[{"question":"What color is the GV4PE03N?","answer":"The enclosure color is gray RAL 7016."},{"question":"What is the depth of this motor circuit breaker?","answer":"Depth is 4.6 in (116 mm)."},{"question":"What compliance documentation is available for the GV4PE03N?","answer":"It is certified to CSA C22.2 No 60947-4-1, UL 60947-4-1, and EN/IEC 60947-4-1 and 60947-2. Fire resistance tested to 960 °C (IEC 60695-2-11)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PE03N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PE03N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}