{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PE115B","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PE115B","canonicalUrl":"https://aoctrl.com/schneider/GV4PE115B","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PE115B","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 series, GV4PE115B, 3-pole motor circuit breaker, 115 A, electronic thermal-magnetic trip, 50 kA Icu at 240 V AC.","salesMarkdown":"The GV4PE115B is a Schneider Electric TeSys GV4 motor circuit breaker rated for 115 A continuous current in AC-3 motor duty, with a magnetic trip threshold of 1955 A and a breaking capacity of 50 kA at 240 V AC per IEC 60947-2. ## Ratings and selection Rated for 115 A line current, this breaker covers motors up to 55 kW at 400 V or 90 kW at 660 V. The electronic thermal-magnetic trip provides adjustable overload and fixed magnetic protection. Magnetic pickup is set at 1955 A, which is 17x In, suited for starting high-inrush loads without nuisance tripping. Breaking capacity is graded by voltage: 50 kA at 240 V, 25 kA at 415 V, and 10 kA at 500 V AC per IEC 60947-2. The UL 60947 listing shows 35 kA at 240 V and 18 kA at 480Y/277 V. Operation classed as Category A (no intentional short-time delay) per IEC 60947-2, and AC-3 motor switching per IEC 60947-4-1. Electrical durability is 10,000 cycles at AC-3 at rated current, and 5,000 cycles at 2x In. ## Compliance and physical Listed to UL 60947-4-1 and CSA C22.2 No 60947-4-1, meeting EN/IEC 60947-4-1 and EN/IEC 60947-2. Fire resistance tested to 960 °C per IEC 60695-2-11. IP40 enclosure, IK07 mechanical impact. Operating altitude up to 5000 m, pollution degree 3. Dimensions: 6.1 in (155 mm) high, 3.2 in (81 mm) wide, 4.6 in (116 mm) deep. Color is gray RAL 7016. Connections use EverLink BTR screw terminals accepting solid or flexible conductors up to 95 mm².","metaTitle":"Schneider GV4PE115B TeSys GV4 Motor Circuit Breaker, 115A","metaDescription":"Active production. GV4PE115B 3-pole motor circuit breaker, 115 A, 50 kA breaking capacity at 240 V. UL, CSA, IEC 60947 certified. Source to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"37 kW 400...415 V AC 50/60 Hz 45 kW 400...415 V AC 50/60 Hz 55 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 500 V AC 50/60 Hz 75 kW 500 V AC 50/60 Hz 75 kW 660...690 V AC 50/60 Hz 90 kW 660...690 V AC 50/60 Hz 110 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PE","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"115 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Electronic Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"EverLink BTR screw connectors top) 1 0.002...0.1 in² (1.5...70 mm²) - solid EverLink BTR screw connectors top) 1 0.002...0.08 in² (1.5...50 mm²) - flexible EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...95 mm²) - solid EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...70 mm²) - flexible","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"1955 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$106.68","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0e0640073751c655467e0b465cbac9ca.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PE115B/alternatives.json"},"ai":{"faq":[{"question":"What is the listed color of the GV4PE115B?","answer":"The enclosure is gray, RAL 7016."},{"question":"What is the depth of the GV4PE115B?","answer":"The depth is 4.6 inches (116 mm)."},{"question":"What compliance documentation does Schneider provide for the GV4PE115B?","answer":"It meets UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. Fire resistance to IEC 60695-2-11 at 960 °C is also listed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PE115B","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PE115B when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}