{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PE80B6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PE80B6","canonicalUrl":"https://aoctrl.com/schneider/GV4PE80B6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PE80B6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 GV4PE80B6 motor circuit breaker, 80 A, 3-pole, electronic thermal-magnetic trip, 50 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.","salesMarkdown":"The GV4PE80B6 is a 3-pole motor circuit breaker from the TeSys Deca range, rated 80 A line current and built for continuous motor protection duty per IEC 60947-4-1. That 80 A rating sets the thermal overload threshold — the breaker holds continuously at 80 A and trips on sustained overcurrent above that level, protecting the motor winding without nuisance tripping on normal starting inrush. The electronic thermal-magnetic trip unit combines two protection modes: an electronic thermal element that tracks motor heating with an adjustable time curve, and a fixed magnetic trip set at 1360 A for short-circuit protection. Phase failure sensitivity per IEC 60947-4-1 means the breaker detects a lost phase and trips before single-phasing damages the motor — no separate phase-loss relay needed. Under UL 60947, the SCCR is 35 kA at 240 V and 18 kA at 480Y/277 V. These numbers govern your coordination study — the breaker must clear a fault within its rated interrupting capacity without upstream devices having to open. ## Isolation and lockout — rated for safe de-energization The GV4PE80B6 is certified suitable for isolation per IEC 60947-1. That means when the toggle is in the OFF position, the contacts provide a visible air gap that meets the isolation standard — you can positively disconnect the motor for maintenance and lock the toggle. No exceptions: if it's not locked, it's not safe. The toggle control type supports padlock hasp attachment for LOTO compliance. ## Certifications and compliance — UL, CSA, IEC on the nameplate That covers North American and European installations from a single part number — no dual-stock needed for a machine shipping to both markets. The fire resistance rating is 960 °C per IEC 60695-2-11, so it passes the glow-wire test for unattended equipment.","metaTitle":"Schneider GV4PE80B6 TeSys Deca Motor Circuit Breaker, 80 A","metaDescription":"Schneider Electric GV4PE80B6 TeSys GV4 motor circuit breaker, 80 A rated current, 3-pole, electronic thermal-magnetic trip, 50 kA breaking capacity at 240 V.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Voltage":"690 V AC 50/60 Hz IEC 60947-2","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Trip Unit Type":"Electronic Thermal-magnetic","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947","Insulation Voltage Ui":"800 V AC 50/60 Hz IEC 60947-2","Operating Position":"Any position","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-58...185 °F (-50...85 °C)","Utilization Category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical Life Cycles":"14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In","Mechanical Life Cycles":"40000 cycles","Main Product Or Component Type":"Motor circuit breaker","Ambient Air Temperature Operation":"-13...158 °F (-25...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/GV4PE80B6/motor-circuit-breaker-tesys-gv4-tesys-gv4-3p-80a-icu-25ka-thermal-magnetic-lugs-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PE80B6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PE80B6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PE80B6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}