{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM02N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM02N6","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM02N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM02N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM02N6, 3-pole, line rated 2 A, electronic thermal-magnetic trip, IP40, gray RAL 7016.","salesMarkdown":"## Motor protection for the TeSys Deca frame The GV4PEM02N6 is a 3-pole motor circuit breaker on the TeSys Deca frame, line rated for 2 A continuous. The electronic thermal-magnetic trip unit combines adjustable overload protection with a fixed magnetic pickup of 34 A for short-circuit clearance. Rated for AC-3 duty (motors), it delivers 100 kA Icu breaking capacity at 240 V AC and 50 kA at 415 V AC per IEC 60947-2. For UL 60947 listings, 65 kA at 240 V and 35 kA at 480Y/277 V. Phase failure sensitivity is included; the breaker isolates the motor on single-phasing conditions. Continuous duty rated per IEC 60947-4-1. ## Physical integration and environmental ratings Enclosure is IP40 with IK07 mechanical impact protection, gray RAL 7016. Depth 4.6 in (116 mm), width 3.2 in (81 mm), height 6.1 in (155 mm). Pollution degree 3, operating altitude up to 5000 m. Connection pitch is 1.06 in (27 mm) without spreaders, 1.4 in (35 mm) with. Terminals accept lugs or ring terminals; tightening torque for the power circuit is 79.7 lbf·in (9 N·m) for 16–95 mm² conductors, 44.3 lbf·in (5 N·m) for 1.5–10 mm². Mechanical and electrical durability: 40,000 cycles for both (AC-3 at 440 V In). Maximum operating rate 25 cycles/h. Vibration and shock tested per IEC 60068-2-6 and -2-27. The GV4PEM02N6 is listed under UL 60947-4-1 and CSA C22.2 No 60947-4-1, plus EN/IEC 60947-4-1 and EN/IEC 60947-2. Fire resistance rated to 1760 °F (960 °C) per IEC 60695-2-11. This is a current-production part (lifecycle stage: current). Submit an inquiry for lead time and pricing.","metaTitle":"Schneider GV4PEM02N6 Motor Circuit Breaker, 2A, 3P, TeSys De","metaDescription":"TeSys GV4 motor circuit breaker rated 2 A, 3-pole, electronic thermal-magnetic trip. Breaking capacity up to 100 kA at 240 V. Complies with UL/CSA/IEC 60947. Current production, so","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"0.25 kW 400...415 V AC 50/60 Hz 0.37 kW 400...415 V AC 50/60 Hz 0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 0.55 kW 660...690 V AC 50/60 Hz 0.75 kW 660...690 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PEM","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"2 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Electronic Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"34 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc88fe9e394965dc167bdd644d7f3983.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM02N6/alternatives.json"},"ai":{"faq":[{"question":"What color is the GV4PEM02N6?","answer":"Gray RAL 7016."},{"question":"What is the depth of the GV4PEM02N6?","answer":"4.6 in (116 mm)."},{"question":"What compliance standards does the GV4PEM02N6 meet?","answer":"UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. Fire resistance tested to 960 °C (IEC 60695-2-11)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM02N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM02N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}