{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV4PEM07N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV4PEM07N6","canonicalUrl":"https://aoctrl.com/schneider/GV4PEM07N6","factsUrl":"https://aoctrl.com/api/mcp/products/GV4PEM07N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM07N6, 7 A, 3-pole, thermal-magnetic, Gray RAL 7016.","salesMarkdown":"The Schneider GV4PEM07N6 is a 7 A, 3-pole motor circuit breaker from the TeSys Deca range, rated for motor protection with a 100 kA breaking capacity at 240 V AC — that SCCR headroom covers most 240 V panels without a downstream fuse. Magnetic tripping current is set at 119 A, so on a short-circuit above that threshold it opens fast, while the thermal-magnetic element handles overload profiles per IEC 60947-4-1. The motor power kW table covers from 1.5 kW up to 7.5 kW depending on voltage (400–690 V AC), which gives flexibility across common European and North American line voltages. Electrical durability is rated at 40,000 cycles at AC-3 440 V, so it's built for moderate-duty motor starts. Dimensions are 6.1 in high, 3.2 in wide, 4.6 in deep — fits a compact panel footprint. Connection pitch is 27 mm without spreaders, 35 mm with; terminals accept lugs or ring terminals up to 95 mm². Operates in any position, IP40 front, IK07 impact resistance. For panel heat, each pole dissipates 4.6 W at rated current.","metaTitle":"Schneider GV4PEM07N6 TeSys GV4 Motor Circuit Breaker, 7A","metaDescription":"Active production motor circuit breaker, 7 A, 3-pole, 100 kA breaking at 240 V. Thermal-magnetic trip, IEC/UL listed. Source to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Gray RAL 7016)","Depth":"4.6 in (116 mm)","Range":"TeSys Deca","Width":"3.2 in (81 mm)","Height":"6.1 in (155 mm)","Category":"US10I1122365","Standards":"CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2","Rated duty":"Continuous IEC 60947-4-1","Control Type":"Toggle","Product name":"TeSys GV4","Motor power kW":"1.5 kW 400...415 V AC 50/60 Hz 2.2 kW 400...415 V AC 50/60 Hz 2.5 kW 400...415 V AC 50/60 Hz 3 kW 400...415 V AC 50/60 Hz 2.2 kW 500 V AC 50/60 Hz 2.5 kW 500 V AC 50/60 Hz 3 kW 500 V AC 50/60 Hz 4 kW 500 V AC 50/60 Hz 3 kW 660...690 V AC 50/60 Hz 4 kW 660...690 V AC 50/60 Hz 5.5 kW 660...690 V AC 50/60 Hz 7.5 kW 660...690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders","Pollution degree":"3","Range of Product":"TeSys GV4","Breaking capacity":"100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947","Device short name":"GV4PEM","Poles description":"3P","Tightening torque":"79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"7 A","Operating altitude":"5000 m","Operating position":"Any position","Trip unit technology":"Thermal-magnetic Electronic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1","Electrical durability":"40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In","Mechanical durability":"40000 cycles","Mechanical robustness":"Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Maximum Operating Rate":"25 cyc/h","Connections - terminals":"Lugs-ring terminals","IK degree of protection":"IK07 IEC 62262","IP degree of protection":"IP40 IEC 60529","Magnetic tripping current":"119 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"4.6 W","[Ui] rated insulation voltage":"800 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2","[Ith] conventional free air thermal current":"115 A IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$110.49","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc88fe9e394965dc167bdd644d7f3983.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV4PEM07N6/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings?","answer":"Rated current 7 A, 3-pole, magnetic trip at 119 A, breaking capacity up to 100 kA at 240 V AC. Thermal-magnetic trip, category A, AC-3 duty. Phase failure sensitive."},{"question":"What compliance standards does it meet?","answer":"Listed to UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN/IEC 60947-4-1. Also meets EN/IEC 60947-2 for circuit-breaker function."},{"question":"What color is the enclosure?","answer":"Gray RAL 7016."},{"question":"What is the physical depth?","answer":"4.6 in (116 mm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV4PEM07N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV4PEM07N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}